show port information

show port {mgmt |port_list | tag tag} information {detail}

Description

Displays detailed system-related information.

Syntax Description

mgmt Specifies the management port.
port_list Specifies one or more ports of slots and ports.
tag Specifies an 802.1Q or 802.1ad tag value.
detail Specifies detailed port information.

Default

N/A.

Usage Guidelines

This command displays information, including the following:

  • Port number
  • Port configuration
    • Virtual router
    • Type of port
    • Admin state
    • Link state and speed
    • Link Up/Down Transition
    • VLAN (Virtual LAN) configuration
    • STP (Spanning Tree Protocol) configuration
    • Trunking, or load sharing
    • EDP (Extreme Discovery Protocol)
    • ELSM (disabled; or if enabled, the ELSM link state is shown as well)
    • Load balancing
    • Learning
    • Link-flap detection status
    • Egress flooding
    • Jumbo frames
    • Link port up/down traps
    • Port isolation status
    • QoS (Quality of Service) profiles
    • VMAN status
    • Smart Redundancy status
    • SRP status
    • Additional platform-specific information
    • Port partition information
    • IEEE Forward Error Correction (FEC) Clause 74 or 91 modes status

If you do not specify a port number, range of ports, or tag value, detailed system-related information is displayed for all ports. The data is displayed in a table format.

The tag value may be associated with either a VMAN or a VLAN.

This status information may be useful for your technical support representative if you have a network problem.

The detail parameter is used to provided more specific port information. The data is called out with written explanations versus displayed in a table format.

Note

Note

The keyword detail displays slightly different information depending on the platform and configuration you are working with.

The link filter counter displayed with the detail keyword is calculated at the middle layer on receiving an event. The link filter up indicates the number of link transitions from down to up at the middle layer filter.

Example

The following command displays port system-related information on a switch:

# show ports 25 information 
                                        ELSM/                                        
Port      Flags               Link       OAM/   Link Num  Num   Num Jumbo QOS     Load
                              State     MACsec   UPS STP VLAN Proto  Size profile Master
========================================================================================
25        Em---------fMB-S-x- active    - / -/up   3   0    1     1  9216 none    
========================================================================================
> indicates Port Display Name truncated past 8 characters
Flags : a - Load Sharing Algorithm address-based,
        b - Rx and Tx Flow Control Enabled, B - Broadcast Flooding Enabled,
        D - Port Disabled, e - Extreme Discovery Protocol Enabled,
        E - Port Enabled, f - Unicast Flooding Enabled,
        F - Priority Flow Control Enabled, G - MLAG Enabled, i - Isolation,
        j - Jumbo Frame Enabled, l - Load Sharing Enabled,
        L - Extreme Link Status Monitoring Enabled,
        m - MACLearning Enabled, M - Multicast Flooding Enabled,
        n - Ingress TOS Enabled, o - Dot1p Replacement Enabled,
        O - Ethernet OAM Enabled, p - Load Sharing Algorithm port-based,
        P - Software redundant port(Primary),
        R - Software redundant port(Redundant),
        s - diffserv Replacement Enabled, S - MACsec Enabled,
        v - Vman Enabled, w - MACLearning Disabled with Forwarding,
        x - Rx Flow Control Enabled
The following command displays detailed information for port 25 on a switch:
# show ports 25 information detail
Port:   25
        Virtual-router: VR-Default
        Type:           UTP 
        Random Early drop:      Unsupported
        Admin state:    Enabled with  auto-speed sensing  auto-duplex
        MACsec Link State:      Up
        Link State:     Active, 1Gbps, full-duplex
        Link Ups:       3        Last: Fri Dec 08 16:26:55 2017
        Link Downs:     1        Last: Fri Dec 08 16:18:12 2017

        VLAN cfg: 
                 Name: MACsec_1000, Internal Tag = 1000, MAC-limit = No-limit, Virtual router:   VR-Default
        STP cfg:

        Protocol: 
                 Name: MACsec_1000  Protocol: ANY      Match all protocols.
        Trunking:       Load sharing is not enabled.

        EDP:            Disabled

        EEE:            Disabled
        ELSM:           Disabled
        Ethernet OAM:           Disabled
        MACsec:         Enabled

The following example displays the current status of non-Extreme optical devices:

 # show ports 3 information detail
Port:   3        
        Virtual-router: VR-Default        
        Type:            Q+SR4       (Licensed)       or                                
                                     (Unlicensed)     or                                                               
                                     (Restricted)                          
        Random Early drop:       Unsupported        
        Admin state:     Enabled        
        Link State:      Ready        
        Link Ups:        0         Last:  --        
        Link Downs:      0         Last: --                 
        VLAN cfg:                  
                Name: Default, Internal Tag = 1, MAC-limit = No-limit, Virtual router:   VR-Default        
        STP cfg:   
                s0(disable), Tag=(none),  Mode=802.1D, State=FORWARDING         
        Protocol:                   
                Name: Default       Protocol: ANY       Match all protocols.        
        Trunking:        Load sharing is not enabled.         
        EDP:             Enabled        
        ELSM:            Disabled        
        Ethernet OAM:            Disabled        
        Learning:         Enabled        
        Unicast Flooding:        Enabled        
        Multicast Flooding:      Enabled        
        Broadcast Flooding:      Enabled        
        Jumbo:           Disabled         

        Flow Control:    Rx-Pause: Enabled        Tx-Pause:     Disabled        
        Priority Flow Control: Disabled        
        Reflective Relay:        Disabled        
        Link up/down SNMP trap filter setting:   Enabled        
        Egress Port Rate:        No-limit  (Restricted, 10 Gbps maximum)        
        Broadcast Rate:          No-limit        
        Multicast Rate:          No-limit        
        Unknown Dest Mac Rate:   No-limit        
        QoS Profile:     None configured        
        Ingress Rate Shaping :           Unsupported        
        Ingress IPTOS Examination:       Disabled

The following output displays show port info detail that has port-specific tag.

Port:   3        
            Virtual-router: None        
            Type:           BASET         
            Random Early drop:      Unsupported        
            Admin state:    Enabled with  10G full-duplex        
            Link State:     Active, 1Gbps, full-duplex        
            Link Ups:       0        Last: Wed Jun 05 00:29:24 2013        
            Link Downs:     0        Last: --         

            VLAN cfg:       Name: test, 802.1Q Tag = 200, MAC-limit = No-limit,
            Virtual router:   VR-Test                       
                Port-specific VLAN ID: 10, 11, 200                 
            Name: test2, 802.1Q Tag = 300, MAC-limit = No-limit,
            Virtual router:   VR-Default        
            STP cfg:         
            Protocol:         
            Trunking:       Load sharing is not enabled.         

            EDP:            Disabled        
            ELSM:           Disabled        
            Ethernet OAM:           Disabled        
            Learning:       Enabled        
            Unicast Flooding:       Enabled        
            Multicast Flooding:     Enabled        
            Broadcast Flooding:     Enabled        
            Jumbo:  Enabled, MTU= 9216         

            Flow Control:   Rx-Pause: Enabled       Tx-Pause: Disabled        
            Priority Flow Control: Disabled        
            Reflective Relay:       Disabled        
            Link up/down SNMP trap filter setting:  Enabled        
            Egress Port Rate:       No-limit        
            Broadcast Rate:         No-limit        
            Multicast Rate:         No-limit        
            Unknown Dest Mac Rate:  No-limit        
            QoS Profile:    None configured        
            Ingress Rate Shaping :          Unsupported        
            Ingress IPTOS Examination:      Disabled        
            Ingress 802.1p Examination:     Enabled        
            Ingress 802.1p Inner Exam:      Disabled        
            Egress IPTOS Replacement:       Disabled        
            Egress 802.1p Replacement:      Disabled        
            NetLogin:                       Disabled        
            NetLogin port mode:             Port based VLANs        
            Smart redundancy:               Enabled        
            Software redundant port:        Disabled        
            IPFIX:   Disabled               Metering:  Ingress, All Packets, All Traffic                
            IPv4 Flow Key Mask:     SIP:  255.255.255.255            DIP: 255.255.255.255                 
            IPv6 Flow Key Mask:     SIP:  ffff:ffff:ffff:ffff:ffff:ffff:ffff:ffff                                         
            DIP:   ffff:ffff:ffff:ffff:ffff:ffff:ffff:ffff          

            Far-End-Fault-Indication:       Disabled        
            Shared packet buffer:           default        
            VMAN CEP egress filtering:      Disabled        
            Isolation:                      Off        
            PTP Configured:                 Disabled        
            Time-Stamping Mode:             None
            Configured Port Partition:      4x10G
            Current Port Partition:         4x10G
            Available Port Partitions:      1x40G, 4x10G, 1x100G, 2x50G, 4x25G        
            Synchronous Ethernet:           Unsupported        
            Dynamic VLAN Uplink:            Disabled        
            VM Tracking Dynamic VLANs:      Disabled
            Forward-Error-Correction:       Disabled

History

This command was first available in ExtremeXOS 10.1.

Information on ingress rate shaping was added in ExtremeXOS 11.0.

Network Login, Smart Redundancy, and rate limiting were added in ExtremeXOS 11.1.

Information on unicast, multicast, and broadcast flooding; the Port not present parameter; and autopolarity status were added in ExtremeXOS 11.2.

The netlogin parameters were added in ExtremeXOS 11.3.

The output command was modified in ExtremeXOS 12.1 so that when learning is disabled with the disabled learning port command, a new w flag appears in the output.

Link Ups and Link Downs information was added to the output and the tag value was added to the command syntax in ExtremeXOS 12.4.4.

Industrial Temperature detail added to Type field in ExtremeXOS 15.1.2.

Note

Note

The Industrial Temperature detail is only displayed only when detail is used. Without it, the output is compressed and the optic type is not displayed.

The show output was enhanced to display the SNMP ifMib ifAlias accessible string size information.

The show output was updated to include the current status of non-Extreme optical devices in ExtremeXOS 15.4.

Link-flap detection information was added in ExtremeXOS 22_1.

Available Port Partitions was added to show port speed licensing information for ExtremeSwitching X870-96x-8c switches in ExtremeXOS 22.2.

IEEE Forward Error Correction (FEC) Clause 74 or 91 modes status was added in ExtremeXOS 22.3.

MACsec information was adde in ExtremeXOS 22.5.

Platform Availability

This command is available on the Summit X450-G2, X460-G2, X670-G2, X770, and ExtremeSwitching X440-G2, X590, X620, X690, X870 series switches.