Disables a load-sharing group of ports, also known as a LAG (Link Aggregation Group).
port |
Specifies the logical port of a load-sharing group or link aggregation group (LAG). Specifies a port or a combination of the slot and port number. |
Disabled.
When sharing is disabled, the logical port retains all configuration including VLAN (Virtual LAN) membership. All other member ports are removed from all VLANs to prevent loops and their configuration is reset to default values.
Any attempt to disable sharing on ports that have MLAG (Multi-switch Link Aggregation Group) configuration is denied with the following error message:
ERROR: Sharing configuration on MLAG ports cannot be modified. Use "disable mlag port <port>" to remove port from MLAG group first.The following command disables sharing on master logical port 9, which contains ports 9 through 12, on a switch:
disable sharing 9
This command was first available in ExtremeXOS 10.1.
This command is available on the Summit X450-G2, X460-G2, X670-G2, X770, and ExtremeSwitching X440-G2, X590, X620, X690, X870 series switches.