In an Extended Edge Switching environment, shows the bridge port extender (BPE) topology that is connected to the specified native cascade port.
|
If a port is not specified, then summary (connected VPEX slot numbers only) information appears by default; if a port is specified, then detailed (VPEX slot interconnections) information appears by default.
If a port is not entered or summary is selected, all topologies appear (summary mode). Only the native cascade port or MLAG and a list of slots appear in summary mode.
If a port is entered or detail is selected, detailed mode information appears. For a ring topology, the command shows both cascades that form a ring, including the dynamically created cascade ports and assigned backup roles. Thus the BPE in each cascade appears twice, one in each cascade.
Severed rings also appear as a pair of cascades with all upstream or cascade ports not being identified as backup. The cascades also indicate that the BPE has been dynamically created (configured) in its position in the cascade. If a native cascade port is not specified, then all topologies appear. Otherwise, only the topology connected to the CB‘s cascade port appears.
For slots configured using virtual MLAG, instead of the native cascade port, the MLAG ID appears.
# show vpex topology port 1:3 Topology: Ring (severed) Native cascade port 1:3 (MLAG id 10) Upstream Cascade Cascade Slot Port Port Flags Slot ---- -------- ------- ----- ------- 108 49 50 109 109 49 50 S 110 ---- -------- ------- ----- ------- MLAG peer “vpexpeer” id 11 Upstream Cascade Cascade Slot Port Port Flags Slot ---- -------- ------- ----- ------- 115 49 50 114 114 49 50 113 113 49 50 112 112 49 50 d 111 111 50 49 d 110 110 50 40 dS 109 ---- -------- ------- ----- ------- * - Port is a member of a load sharing group Flags: (b) Backup Upstream Port, (B) Backup Cascade Port, (c) Common ring link on this BPE (d) Dynamically Created Cascade Port, (E) Empty slot, (S) Severed ring link on this BPE.
# show vpex topology Topology: Ring (Complete) Native cascade port 1:1 Slots: 100, 101, 102, 103, 104, 105, 106, 107 Native cascade port 1:2 Slots: 107, 106, 105, 104, 103, 102, 101, 100 Topology: Ring (Severed) Native cascade port 1:3 (MLAG id 10) Slots: 108, 109 MLAG ID 11 Slots: 115, 114, 113, 112, 111, 110 Topology: Cascade Native cascade port 1:4 Slots: 116, 117, 118, 119, 120
This command was first available in ExtremeXOS 22.7.
This command is available on the Summit X670-G2 and ExtremeSwitching X690, X590 series switches.