Shows the status of Extended Edge Switching VPEX mode, auto-configuration (partial automation) and Zero Touch Provisioning (ZTP) (full automation) status, ring re-balancing status, and if applicable, switch port to bridge port extender (BPE) slot assignments.
This command has no arguments or variables.
N/A.
The following example shows VPEX mode, auto-configuration, and ring re-balancing are enabled, and that switch port 1:20 is attached to a BPE assigned to slot number 100:
# show vpex Virtual Port Extender: Enabled Auto-Configuration: Enabled Ring rebalancing: Auto Zero Touch Provisioning: Nothing Provisioned - Existing configuration present Cascade Port/MLAG Id Slot ==================== 1:20 100
The following example shows that VPEX mode is disabled:
# show vpex Virtual Port Extender: Disabled
This command was first available in ExtremeXOS 22.5.
Auto-configuration status information was added in ExtremeXOS 22.6.
Ring re-balancing and Zero Touch Provisioning (ZTP) information was added in ExtremeXOS 22.7.
This command is available on the Summit X670-G2 and ExtremeSwitching X690, X590 series switches.