Shows power supply, temperature, and fan status for bridge port extenders (BPE).
| vpex | Specifies Virtual Port Extender (VPEX). |
| bpe | Bridge port extender (BPE). |
| slot | Specifies a specific port extender by slot number. |
| slot_num | Specifies a specific port extender by slot number. |
| environment | Specifies port extender environment information, including PSU, fan, and temperature information. |
N/A.
When an extended slot is configured using MLAG-ID and its peer, the MLAG ID could be associated with a port or it could be a virtual MLAG ID. For slots configured using virtual MLAG, instead of the cascade port, the MLAG ID appears in output of this command.
The following example shows environment information for all BPEs attached to the switch. In this case, there are two BPEs: one attached on port 1:45 and assigned to slot 100, and another attached on port 1:45 and assigned to slot 101:
# show vpex bpe environment
BPE Environment Information
Cascade Port: 1:41 Slot: 100 MAC: d8:84:66:88:98:74
Description: Floor1
Serial #: 800879-00-00 1716A042010
Main PSU: Powered On
Backup PSU: Empty
Fan-1: Operational at 5434 RPM
Sensor-1: Operational Temp: Normal
Sensor-2: Operational Temp: Normal
Sensor-3: Operational Temp: Normal
Sensor-4: Operational Temp: Normal
Cascade Port: 1:45 Slot: 101 MAC: d8:84:66:88:97:fa
Description: Floor2
Serial #: 00.00.01 1705D-10009
Main PSU: Powered On
Backup PSU: Empty
Fan-1: Operational at 10621 RPM
Sensor-1: Operational Temp: Normal
Sensor-2: Operational Temp: Normal
Sensor-3: Operational Temp: Normal
Sensor-4: Operational Temp: Normal
This command was first available in ExtremeXOS 22.5.
MLAG ID information added in ExtremeXOS 22.7.
This command is available on the Summit X670-G2 and ExtremeSwitching X690, X590 series switches.