Disables the egress filtering of CVIDs that are not configured in the CVID map for a CEP.
port_list | Specifies a list of ports. |
all | Specifies all switch ports. |
Egress CVID filtering is disabled.
To view the configuration setting for the egress CVID filtering feature, use the show ports information command.
Note
When CVID egress filtering is enabled, it reduces the maximum number of CVIDs supported on a port. The control of CVID egress filtering applies to fast-path forwarding. When frames are forwarded through software, CVID egress filtering is always enabled.The following example disables egress CVID filtering on port 1:
disable vman cep egress filtering port 1
This command was first available in ExtremeXOS 12.6.