configure inline-power detection ports
configure inline-power detection [802.3af-only | legacy-and-802.3af [4-point
| 2-point] | bypass]
ports port_list
Description
This command configures PoE (Power over Ethernet) device
detection mode for Extreme Networks PoE devices and SummitStack. Summit platforms support
per-port basis configuration.
Syntax Description
802.3af-only
|
IEEE 802.3af detection only. |
legacy-and-802.3af |
Capacitive and IEEE 802.3aqf
detection. |
4-point |
Selects 4-point detection (default). |
2-point |
Selects 2-point detection (for extended
detection signature range). |
bypass |
No detection phase. |
port_list |
Port list separated by a comma or - . |
Default
Default is 4-point detection.
Example
X460G2-24p-G4.4 # show inline-power configuration ports 1-2
Port Config Operator Limit Priority Detection Label
1 Enabled 30000 mW Low 802.3af-only
2 Enabled 30000 mW Low legacy-and-802.3af
History
This command was first available in ExtremeXOS 16.1.
4-point and 2-point detection options were
added in ExtremeXOS 22.5.
Platform Availability
This command is available on:
- Summit X450-G2-24p-GE4—ExtremeXOS 16.1 and later
- Summit X450-G2-48p-GE4—ExtremeXOS 16.1 and later
- Summit X450-G2-24p-10GE4—ExtremeXOS 16.1 and later
- Summit X450-G2-48p-10GE4—ExtremeXOS 16.1 and later
- Summit X460-G2-24p-10GE4—ExtremeXOS 15.6 and later
- Summit X460-G2-48p-10GE4—ExtremeXOS 15.6 and later
- Summit X460-G2-24p-GE4—ExtremeXOS 15.6 and later
- Summit X460-G2-48p-GE4—ExtremeXOS 15.6 and later
- Summit X460-G2-16mp-32p-10GE4—ExtremeXOS 15.6 and later
- ExtremeSwitching
X460-G2-24p-24hp-10GE4—ExtremeXOS 22.2 and later
- ExtremeSwitching X440-G2-48p-10GE4—ExtremeXOS 21.1 and
later
- ExtremeSwitching X440-G2-24p-10GE4—ExtremeXOS 21.1 and
later
- ExtremeSwitching X440-G2-12p-10GE4—ExtremeXOS 21.1 and
later
- ExtremeSwitching X620-16p—ExtremeXOS 22.2 and later