configure inline-power detection ports

configure inline-power detection [802.3af-only | legacy-and-802.3af [4-point | 2-point] | bypass] ports port_list

Description

This command configures PoE (Power over Ethernet) device detection mode for Extreme Networks PoE devices and SummitStack. Summit platforms support per-port basis configuration.

Syntax Description

802.3af-only IEEE 802.3af detection only.
legacy-and-802.3af Capacitive and IEEE 802.3aqf detection.
4-point Selects 4-point detection (default).
2-point Selects 2-point detection (for extended detection signature range).
bypass No detection phase.
port_list Port list separated by a comma or - .

Default

Default is 4-point detection.

Usage Guidelines

None.

Example

X460G2-24p-G4.4 # show inline-power configuration ports 1-2
Port   Config   Operator  Limit  Priority   Detection           Label
1      Enabled     30000  mW     Low        802.3af-only
2      Enabled     30000 mW      Low        legacy-and-802.3af

History

This command was first available in ExtremeXOS 16.1.

4-point and 2-point detection options were added in ExtremeXOS 22.5.

Platform Availability

This command is available on:

  • Summit X450-G2-24p-GE4—ExtremeXOS 16.1 and later
  • Summit X450-G2-48p-GE4—ExtremeXOS 16.1 and later
  • Summit X450-G2-24p-10GE4—ExtremeXOS 16.1 and later
  • Summit X450-G2-48p-10GE4—ExtremeXOS 16.1 and later
  • Summit X460-G2-24p-10GE4—ExtremeXOS 15.6 and later
  • Summit X460-G2-48p-10GE4—ExtremeXOS 15.6 and later
  • Summit X460-G2-24p-GE4—ExtremeXOS 15.6 and later
  • Summit X460-G2-48p-GE4—ExtremeXOS 15.6 and later
  • Summit X460-G2-16mp-32p-10GE4—ExtremeXOS 15.6 and later
  • ExtremeSwitching X460-G2-24p-24hp-10GE4—ExtremeXOS 22.2 and later
  • ExtremeSwitching X440-G2-48p-10GE4—ExtremeXOS 21.1 and later
  • ExtremeSwitching X440-G2-24p-10GE4—ExtremeXOS 21.1 and later
  • ExtremeSwitching X440-G2-12p-10GE4—ExtremeXOS 21.1 and later
  • ExtremeSwitching X620-16p—ExtremeXOS 22.2 and later