Displays the SNMP (Simple Network Management Protocol) and CLI settings configured on the switch and the SNMP statistics.
This command has no arguments or variables.
N/A.
Enable/disable state for Telnet, and SNMP access.
Enable/disable state for idle timeouts.
Maximum number of CLI sessions.
SNMP community strings.
SNMP trap receiver list.
SNMP trap receiver source IP address.
SNMP statistics counter.
SSH access state (enabled/disabled), idle time, rekey interval, and web access.
CLI configuration logging.
SNMP access states of v1, v2c disabled and v3 enabled.
If all three types of SNMP access are enabled or disabled, SNMP access is displayed as either Enabled or Disabled.
For ExtremeXOS 11.1 and later, the following management output appears:
Enable/disable state for RMON.
Access-profile usage configured via ACL (Access Control List)s for additional Telnet and SSH2 security.
Enable/disable state.
Error message setting.
Persistence mode.
For ExtremeXOS 12.4 and later, the following management output appears:
Dropped SNMP packet counter.
CLI prompting.
SNMP INFORM.
For ExtremeXOS 22.1 and later, configured journal size (historical list of commands) appears.
For ExtremeXOS 22.3 and later, SSHv2 rekey interval time appears.
For ExtremeXOS 22.7 and later, CLI history expansion status appears.
The following command displays configured SNMP settings on a switch:
# show management CLI idle timeout : Enabled (20 minutes) CLI max number of login attempts : 3 CLI max number of sessions : 8 CLI paging : Enabled (this session only) CLI space-completion : Disabled (this session only) CLI configuration logging : Disabled (with expansion) CLI journal size : 100 CLI password prompting only : Disabled CLI RADIUS cmd authorize tokens : 2 CLI scripting : Disabled (this session only) CLI scripting error mode : Ignore-Error (this session only) CLI persistent mode : Persistent (this session only) CLI prompting : Enabled (this session only) CLI screen size : 24 Lines 80 Columns (this session only) CLI refresh : Enabled CLI history expansion : Enabled Telnet access : Enabled (tcp port 23 vr all) : Access Profile : not set SSH access : Enabled (Key valid, tcp port 22 vr all) : Secure-Mode : Off : Access Profile : not set SSH2 idle time : 60 minutes SSH2 rekey interval : 4096 MB and no time limit Web access : Enabled (tcp port 80) : Access Profile : not set Total Read Only Communities : 1 Total Read Write Communities : 1 RMON : Disabled SNMP access : Enabled : Access Profile : not set SNMP Notifications : Enabled SNMP Notification Receivers : None SNMP stats: InPkts 0 OutPkts 0 Errors 0 AuthErrors 0 Gets 0 GetNexts 0 Sets 0 Drops 0 SNMP traps: Sent 0 AuthTraps Enabled SNMP inform: Sent 0 Retries 0 Failed 0
This command was first available in ExtremeXOS 10.1.
The trap receiver source IP address, SNMP counter statistics, SSH access, CLI logging, and SNMP access states were added to the output in ExtremeXOS 11.0.
The enabled/disabled state for RMON was added to the output in ExtremeXOS 11.1.
Additional Telnet and SSH2 information about ACL usage was added to the output in ExtremeXOS11.2.
Information about CLI scripting including, the enabled/disabled state, error mode, and persistent mode was added to the output in ExtremeXOS 11.6.
The dropped SNMP packet counter (Drops) was added to the output in ExtremeXOS 12.4.
CLI prompting was added to the output in ExtremeXOS 12.5.
SNMP INFORM was added in ExtremeXOS 12.5.3.
Configured journal size (historical list of commands) was added in ExtremeXOS 22.1.
SSHv2 rekey interval time was added in ExtremeXOS 22.3.
Status of CLI configuration logging unabbreviated form (expansion) was added in ExtremeXOS 22.5.
CLI history expansion status was added in ExtremeXOS 22.7.
This command is available on the Summit X450-G2, X460-G2, X670-G2, X770, and ExtremeSwitching X440-G2, X590, X620, X690, X870 series switches.