show bfd vlan

show bfd vlan {vlan_name}

Description

Displays the BFD settings for the specified VLAN (Virtual LAN).

Syntax Description

vlan_name

Specifies the VLAN name.

Default

N/A.

Usage Guidelines

Use this command to display the BFD settings on a specified VLAN.

Example

The following command displays the BFD settings for the VLAN vlan10:

show bfd vlan vlan10

Following is sample output from this command:

VLAN                 : vlan10
BFD                  : Enabled
Tx Interval          : 1000
Rx Interval          : 1000
Detection Multiplier : 3
Authentication       : None

History

This command was first available in ExtremeXOS 12.4.

Platform Availability

This command is available on the Summit X450-G2, X460-G2, X670-G2, X770, and ExtremeSwitching X440-G2, X590, X620, X690, X870 series switches.