Displays the CPU utilization on the specified bridge port extenders BPE(s).
vpex | Specifies VPEX. |
bpe | Specifies BPE. |
slot | Specifies a specific BPE by slot number. |
slot_num | Specifies a specific BPE by slot number. |
cpu-utilization | Specifies showing CPU information. |
N/A.
When an extended slot is configured using MLAG-ID and its peer, the MLAG ID could be associated with a port or it could be a virtual MLAG ID. For slots configured using virtual MLAG, instead of the cascade port, the MLAG ID appears in output of this command.
The following example shows CPU information for all BPEs attached to the control bridge (CB):
# show vpex bpe cpu-utilization Slot: 100 Cascade Port: 1:44 MAC: d8:84:66:88:98:06 CPU Utilization: 5 seconds: 28 % 1 minute: 16 % 5 minutes: 16 % Slot: 101 Cascade Port: 1:45 MAC: d8:84:66:88:98:07 CPU Utilization: 5 seconds: 29 % 1 minute: 17 % 5 minutes: 18 %
This command was first available in ExtremeXOS 22.5.
MLAG ID information added in ExtremeXOS 22.7.
This command is available on the Summit X670-G2 and ExtremeSwitching X690, X590 series switches.