show vpex bpe cpu-utilization

show vpex bpe {slot slot_num} cpu-utilization

Description

Displays the CPU utilization on the specified bridge port extenders BPE(s).

Syntax Description

vpex Specifies VPEX.
bpe Specifies BPE.
slot Specifies a specific BPE by slot number.
slot_num Specifies a specific BPE by slot number.
cpu-utilization Specifies showing CPU information.

Default

N/A.

Usage Guidelines

When an extended slot is configured using MLAG-ID and its peer, the MLAG ID could be associated with a port or it could be a virtual MLAG ID. For slots configured using virtual MLAG, instead of the cascade port, the MLAG ID appears in output of this command.

Example

The following example shows CPU information for all BPEs attached to the control bridge (CB):

# show vpex bpe cpu-utilization
Slot: 100   Cascade Port: 1:44   MAC: d8:84:66:88:98:06
CPU Utilization:
  5 seconds: 28 %
  1 minute:  16 %
  5 minutes: 16 %

Slot: 101   Cascade Port: 1:45   MAC: d8:84:66:88:98:07
CPU Utilization:
  5 seconds: 29 %
  1 minute:  17 %
  5 minutes: 18 %

History

This command was first available in ExtremeXOS 22.5.

MLAG ID information added in ExtremeXOS 22.7.

Platform Availability

This command is available on the Summit X670-G2 and ExtremeSwitching X690, X590 series switches.