View the Remote I-SID Forwarding Database

Note
This procedure only applies to the VSP 7400 Series.
About this task
Perform this procedure to view the remote I-SID forwarding database (FDB) on the switch.

Note
To view the T-UNI I-SID FDB entries filtered on a port that is part of an MLT, you must mention the MLT ID in the option for the port.
Procedure
- In the navigation pane, expand the folders.
- Select ISID Remote.
- Optional: Select the Filter button to filter the rows on basis of specific criteria.
FDB Field Descriptions
Use data in the following table to use the FDB tab.
| Name | Description | 
|---|---|
| IsidId | Specifies the service interface identifier (I-SID). | 
| Address | Specifies the MAC address of the port assigned to the specific I-SID or C-MAC learned on the particular I-SID. | 
| Status | Specifies the learning status of the associated MAC. | 
| Port | Specifies the port on which the MAC is learned for the specific I-SID. | 
| PortType | Specifies if the MAC address is learned locally or on an NNI port from a remote destination. | 
| RemoteMacDestAddr | Specifies the virtual BMAC address or system-ID of the remote destination. | 
| RemoteMacBVlanId | Specifies the B-VLAN ID on which the remote destination was discovered. | 
| RemoteMacDestSysName | Specifies the remote destination system name. | 
| Cvid | Specifies the customer VLAN ID of the associated Switched UNI port. | 