configure ces filler-pattern

configure ces ces_name filler-pattern byte_value

Description

Configures the filler pattern of the specified CES pseudowire.

Syntax Description

ces_name Alphanumeric string identifying the CES pseudowire.
byte_value Filler pattern to be played out on a timeslot bound to the CES pseudowire. Allowed values are between 0 and 255, with a default of 255.

Default

The default value is 255.

Usage Guidelines

Note that this pattern is played out only on timeslots bound to the CES pseudowire. For unused timeslots, i.e., for timeslots not bound to a CES pseudowire, the fixed pattern of 0xff will be played out.

Example

E4G400#configure ces ces-test filler-pattern 100

History

This command was first available in ExtremeXOS 15.1.

Platform Availability

This command is available on the cell site routers (E4G-200 and E4G-400).