show odometers

show odometers

Description

Displays a counter for each component of a switch that shows how long it has been functioning since it was manufactured.

Syntax Description

This command has no arguments or variables.

Default

N/A.

Usage Guidelines

The output from this command displays how long individual components in the switch have been functioning since it was manufactured. This odometer counter is kept in the EEPROM of each monitored component. On a modular switch, this means that even if you plug in the component into a different chassis, the odometer counter is available in the new switch chassis.

Monitored Components

On a modular switch, the odometer monitors the following components:
  • Chassis.

  • MSMs/MMs.

  • I/O modules.

  • Power controllers.

On the Summit family switches (whether or not included in a SummitStack), the odometer monitors the following components:
  • Switch.

  • XGM-2xn card.

Recorded Statistics

The following odometer statistics are collected by the switch:
  • Service Days—The amount of days that the component has been running.

  • First Recorded Start Date—The date that the component was powered-up and began running.

Depending on the software version running on your switch, the modules installed in your switch, and the type of switch you have, additional or different odometer information may be displayed.

Example

The following command displays how long each component of a switch has been functioning since its manufacture date:

show odometers

The following is sample output from the BlackDiamond X8 series switch:

BD-X8.4 # show odometers
Service  First Recorded
Field Replaceable Units                 Days     Start Date
---------------------------------------------------------------
Chassis        : BD-X8                       41  Oct-28-2011
Slot-1         : BDXA-10G48X                 31  Oct-12-2011
Slot-2         : BDXA-10G48X                 13  Nov-16-2011
Slot-3         :
Slot-4         :
Slot-5         :
Slot-6         : BDXA-40G24X                 27  Nov-22-2011
Slot-7         : BDXA-40G24X                 27  Nov-22-2011
Slot-8         : BDXA-40G24X                 27  Nov-22-2011
FM-1           : BDXA-FM20T                  33  Nov-15-2011
FM-2           : BDXA-FM20T                  33  Nov-15-2011
FM-3           : BDXA-FM20T                  29  Nov-15-2011
FM-4           : BDXA-FM20T                  16  Nov-15-2011
MM-A           : BDX-MM1                     30  Sep-08-2011
MM-B           : BDX-MM1                     52  Sep-09-2011

The following is sample output from the BlackDiamond 8800 series switch:

Field Replaceable Units                 Days     Start Date
---------------------------------------------------------------
Chassis        : BD-8810                   1848  Sep-21-2004
Slot-1         : G48P                      1819  Sep-27-2004
Slot-2         : G24X                       343  Sep-21-2004
Slot-3         : G48T                      1818  Sep-27-2004
Slot-4         :
Slot-5         : G8X                       1632  Sep-21-2004
Slot-6         : G8X                       1231  Sep-28-2004
Slot-7         :
Slot-8         : G48Te                     1435  Feb-06-2006
Slot-9         : G48Ta                     1484  Apr-13-2006
Slot-10        :
MSM-A          : MSM-48C                   1624  Oct-21-2004
MSM-B          : MSM-48C                   1218  Nov-30-2004
PSUCTRL-1      :                           1809  Nov-30-2004
PSUCTRL-2      :                           1821  Nov-29-2004

The following is sample output from a stand-alone Summit series switch:

Service  First Recorded
Field Replaceable Units           Days     Start Date
-------------------------         -------  --------------
Switch     : SummitX             7  Dec-08-2004
XGM-2xn-1  :
														Service  First Recorded
Field Replaceable Units                 Days     Start Date
---------------------------------------------------------------
Switch         : X(SS)               381  Oct-29-2009
VIM1-SS-1      :                            376  Jul-30-2009

History

This command was first available in ExtremeXOS 10.1.

Information about the power controller(s) for modular switches was added to the show odometers output in ExtremeXOS 11.0.

Platform Availability

This command is available on all platforms.