Configures the delay time between successive frame transmissions initiated by a value change or status change in any of the LLDP local systems Management Information Base (MIB).
The auto option uses a formula (0.25 * transmit-interval) to calculate the number of seconds.
auto | Uses the formula (0.25 * transmit-interval) to calculate the seconds. |
seconds | Specifies the interval at which LLDP notifications are sent. The range is 1 to 8291. |
2 seconds.
This is the timer between triggered updates.
The following command configures the delay between LLDP frame transmissions for triggered updates to be automatically calculated:
configure lldp transmit-delay auto
This command was first available in ExtremeXOS 11.2.
This command is available on all platforms.