Displays the specified TDM port error counters.
|
tdm |
Time Division Multiplexing. |
|
errors |
Displays errors. |
|
near-end |
Displays near-end errors (Default). |
|
total |
Displays cumulative errors. |
|
intervals |
Displays errors for 15-minute intervals. |
|
current |
Displays current 15-minute interval errors (Default). |
|
no-refresh |
Page by page display without auto-refresh. |
| refresh | Continuous refresh of output. |
The default will display near-end current error statistics.
Use the current switch lists the error statistics of the on-going 15-minute interval. The intervals switch displays the error statistics for the last 96 instances of 15-minute intervals. The total switch displays the cumulative error statistics.
Only one space is given between the first and second field to accommodate the output within 80 characters.
E4G-400.3 # show port {port_list} tdm errors near-end current
Port Statistics Tue Jul 31 10:20:56 2012
Port LCV/ PCV/ Unavail Error Burst Severe Slip
BPV CRC Secs Secs Err Secs Err Secs Secs
================================================================================
31 0 0 0 0 0 0 0
32 0 0 0 0 0 0 0
================================================================================
> indicates Port Display Name truncated past 8 characters
U->page up D->page down ESC->exit
Legend: BPV - Bipolar Violations, LCV - Line Code Violations,
PCV - Path Code Violations
E4G-400.3 # show port {port_list} tdm errors near-end current no-refresh
Port LCV/ PCV/ Unavail Error Burst Severe Slip
BPV CRC Secs Secs Err Secs Err Secs Secs
================================================================================
31 0 0 0 0 0 0 0
32 0 0 0 0 0 0 0
================================================================================
> indicates Port Display Name truncated past 8 characters
Legend: BPV - Bipolar Violations, LCV - Line Code Violations,
PCV - Path Code Violations
E4G-400.3 # show port {<port_list>} tdm errors near-end intervals
Port/ LCV/ PCV/ Unavail Error Burst Severe Slip
Interval BPV CRC Secs Secs Err Secs Err Secs Secs
================================================================================
31/
1 0 0 0 89 0 0 0
2 0 8 0 0 0 0 12
3 456 0 0 0 0 0 0
96 0 0 0 0 0 0 0
--------------------------------------------------------------------------------
32/
1 0 0 0 0 0 0 0
96 0 0 0 0 0 0
================================================================================
> indicates Port Display Name truncated past 8 characters
Legend: BPV - Bipolar Violations, LCV - Line Code Violations,
PCV - Path Code Violations
E4G-400.3 # show port {port_list} tdm errors near-end total
Port: 31
Line Code Violations / Bipolar Violations : 837483
Path Code Violations / CRC : 289037434
Unavailable Seconds : 38389
Errored Seconds : 284
Bursty Errored Seconds : 297
Severely Errored Seconds : 82
Controlled Slip Seconds : 28
This command was first available in ExtremeXOS 15.1.
The refresh keyword was added in ExtremeXOS 16.1.
This command is available on the cell site routers (E4G-200 and E4G-400).
Print
this page
Email this topic
Feedback