show port information

show port {mgmt | port_list | tag tag} information {detail}

Description

Displays detailed system-related information.

Syntax Description

mgmt

Specifies the management port.

port_list

Specifies one or more ports of slots and ports.

tag

Specifies an 802.1Q or 802.1ad tag value.

detail

Specifies detailed port information.

Default

N/A.

Usage Guidelines

This command displays information, including the following:
  • Port number.

  • Port configuration.
    • Virtual router.

    • Type of port.

    • Admin state.

    • Link state and speed.

    • Link Up/Down Transition.

    • VLAN configuration.

    • STP configuration.

    • Trunking, or load sharing.

    • EDP.

    • ELSM (disabled; or if enabled, the ELSM link state is shown as well).

    • Load balancing.

    • Learning.

    • Egress flooding.

    • Jumbo frames.

    • Link port up/down traps.

    • Port isolation status.

    • QoS profiles.

    • VMAN status.

    • Smart Redundancy status.

    • SRP status.

    • Additional platform-specific information.

If you do not specify a port number, range of ports, or tag value, detailed system-related information is displayed for all ports. The data is displayed in a table format.

The tag value may be associated with either a VMAN or a VLAN.

This status information may be useful for your technical support representative if you have a network problem.

The detail parameter is used to provided more specific port information. The data is called out with written explanations versus displayed in a table format.

Note

Note

The keyword detail displays slightly different information depending on the platform and configuration you are working with.

The link filter counter displayed with the detail keyword is calculated at the middle layer on receiving an event. The link filter up indicates the number of link transitions from down to up at the middle layer filter.

Example

The following command displays port system-related information on a BlackDiamond 8810 switch:

show port 1:5-7 information
Port      Flags              Link           Link Num Num  Num   Jumbo QOS     Load
State     ELSM UPS  STP VLAN Proto Size  profile Master
====================================================================================
1:5       Em------e--fMB---b active     -     1    1    1   1   9216  none
1:6       Em------e--fMB---x ready      -     0    1    1   1   9216  none
1:7       Em------e--fMB---p ready      -     0    1    1   1   9216  none> indicates Port Display Name truncated past 8 characters
Flags : a - Load Sharing Algorithm address-based, D - Port Disabled,
e - Extreme Discovery Protocol Enabled, E - Port Enabled,
g - Egress TOS Enabled, i - Isolation
j - Jumbo Frame Enabled, l - Load Sharing Enabled, 
m - MACLearning Enabled, n - Ingress TOS Enabled, 
o - Dot1p Replacement Enabled, P - Software redundant port(Primary),
R - Software redundant port(Redundant),
q - Background QOS Monitoring Enabled,
s - diffserv Replacement Enabled,
v - Vman Enabled, f - Unicast Flooding Enabled,
M - Multicast Flooding Enabled, B - Broadcast Flooding Enabled
L - Extreme Link Status Monitoring Enabled
O - Ethernet OAM Enabled
w - MACLearning Disabled with Forwarding
b - Rx and Tx Flow Control Enabled, x - Rx Flow Control Enabled
p - Priority Flow Control Enabled

The following command displays detailed information for port 1 on a Summit X670 switch:

X670V-48x.2 #  show port 1 information detail   
Port:   1           
        Virtual-router: VR-Default           
        Type:           Q+PSM4           
        Random Early drop:      Unsupported           
        Admin state:    Enabled with  10G full-duplex           
        Link State:     Active, 10Gbps, full-duplex           
        Link Ups:       1        Last: Wed Feb 06 12:28:48 2013           
        Link Downs:     0        Last: --               

        VLAN cfg:           
        STP cfg:               

        Protocol:           
        Trunking:       Load sharing is not enabled.               

        EDP:            Enabled           
        ELSM:           Disabled           
        Ethernet OAM:           Disabled           
        Learning:       Enabled           
        Unicast Flooding:       Enabled           
        Multicast Flooding:     Enabled           
        Broadcast Flooding:     Enabled           
        Jumbo:          Disabled               

        Flow Control:   Rx-Pause: Enabled       Tx-Pause:      Disabled           
        Priority Flow Control: Disabled           
        Reflective Relay:       Disabled           
        Link up/down SNMP trap filter setting:  Enabled           
        Egress Port Rate:       No-limit           
        Broadcast Rate:         No-limit           
        Multicast Rate:         No-limit           
        Unknown Dest Mac Rate:  No-limit           
        QoS Profile:    None configured           
        Ingress Rate Shaping :          Unsupported           
        Ingress IPTOS Examination:      Disabled           
        Ingress 802.1p Examination:     Enabled          
        Ingress 802.1p Inner Exam:      Disabled          
        Ingress 802.1p Priority:        4 
        Egress IPTOS Replacement:       Disabled           
        Egress 802.1p Replacement:      Disabled           
        NetLogin:                       Disabled           
        NetLogin port mode:             Port based VLANs           
        Smart redundancy:               Enabled           
        Software redundant port:        Disabled           
        IPFIX:   Disabled               Metering:  Ingress, All Packets, All Traffic                  
                IPv4 Flow Key Mask:     SIP: 255.255.255.255            DIP: 
255.255.255.255                   
                IPv6 Flow Key Mask:     SIP: ffff:ffff:ffff:ffff:ffff:ffff:ffff:ffff                                           
                                        DIP: ffff:ffff:ffff:ffff:ffff:ffff:ffff:ffff               
        Far-End-Fault-Indication:       Disabled           
        Shared packet buffer:           default           
        VMAN CEP egress filtering:      Disabled           
        Isolation:                      Off           
        PTP Configured:                 Disabled           
        Time-Stamping Mode:             None          
        Synchronous Ethernet:           Unsupported           
        Dynamic VLAN Uplink:            Disabled           
        VM Tracking Dynamic VLANs:      Disabled   
X670V-48x.3 #    
The following example output displays the current isolation mode of the ports:
show port 21 info detail   
Port:   21           
        Virtual-router: VR-Default           
        Type:           SF+_SR Unsupported Optic Module           
        Random Early drop:      Unsupported           
        Admin state:    Enabled with  10G full-duplex           
        Link State:     Active, 10Gbps, full-duplex           
        Link Ups:       1        Last: Wed Feb 06 12:28:48 2013           
        Link Downs:     0        Last: --               

        VLAN cfg:           
        STP cfg:               

        Protocol:           
        Trunking:       Load sharing is not enabled.               

        EDP:            Enabled           
        ELSM:           Disabled           
        Ethernet OAM:           Disabled           
        Learning:       Enabled           
        Unicast Flooding:       Enabled           
        Multicast Flooding:     Enabled           
        Broadcast Flooding:     Enabled           
        Jumbo:          Disabled               

        Flow Control:   Rx-Pause: Enabled       Tx-Pause:      Disabled           
        Priority Flow Control: Disabled           
        Reflective Relay:       Disabled           
        Link up/down SNMP trap filter setting:  Enabled           
        Egress Port Rate:       No-limit           
        Broadcast Rate:         No-limit           
        Multicast Rate:         No-limit           
        Unknown Dest Mac Rate:  No-limit           
        QoS Profile:    None configured           
        Ingress Rate Shaping :          Unsupported           
        Ingress IPTOS Examination:      Disabled           
        Ingress 802.1p Examination:     Enabled          
        Ingress 802.1p Inner Exam:      Disabled           
        Egress IPTOS Replacement:       Disabled           
        Egress 802.1p Replacement:      Disabled           
        NetLogin:                       Disabled           
        NetLogin port mode:             Port based VLANs           
        Smart redundancy:               Enabled           
        Software redundant port:        Disabled           
        IPFIX:   Disabled               Metering:  Ingress, All Packets, All Traffic                  
                IPv4 Flow Key Mask:     SIP: 255.255.255.255            DIP: 255.255.255.255                   
                IPv6 Flow Key Mask:     SIP: ffff:ffff:ffff:ffff:ffff:ffff:ffff:ffff                                           
                                        DIP: ffff:ffff:ffff:ffff:ffff:ffff:ffff:ffff               
        Far-End-Fault-Indication:       Disabled           
        Shared packet buffer:           default           
        VMAN CEP egress filtering:      Disabled           
        Isolation:                      Off           
        PTP Configured:                 Disabled           
        Time-Stamping Mode:             None          
        Synchronous Ethernet:           Unsupported           
        Dynamic VLAN Uplink:            Disabled           
        VM Tracking Dynamic VLANs:      Disabled             


show port 21-23 info   
Port      Flags               Link       ELSM Link Num Num  Num   Jumbo QOS     Load     
                              State     /OAM UPS  STP VLAN  Proto Size  profile Master   
=====================================================================================   
21        Emj-----e--fMB---xi active    - / -  1    0   
        1   0   1600  none   22       
          Emj-----e--fMB---xi active    - / -  1    0   
        1   0   1600  none   23       
          Emj-----e--fMB---x- ready     - / -  0    0   
        0   0   1600  none   
=====================================================================================   
> indicates Port Display Name truncated
        past 8 characters   
Flags : a - Load Sharing Algorithm address-based, D - Port Disabled,           
        e - Extreme Discovery Protocol Enabled, E - Port Enabled,           
        g - Egress TOS Enabled, i – Isolation, j - Jumbo Frame Enabled,           
        l - Load Sharing Enabled, m - MACLearning Enabled,           
        n - Ingress TOS Enabled,
        o - Dot1p Replacement Enabled,           
        P - Software redundant port(Primary),           
        R - Software redundant port(Redundant),           
        q - Background QOS Monitoring Enabled,           
        s - diffserv Replacement Enabled,           
        v - Vman Enabled, f - Unicast Flooding Enabled,           
        M - Multicast Flooding Enabled, B - Broadcast Flooding Enabled           
        L - Extreme Link Status Monitoring Enabled           
        O - Ethernet OAM Enabled           
        w - MACLearning Disabled with Forwarding           
        b - Rx and Tx Flow Control Enabled, x - Rx Flow Control Enabled           
        p - Priority Flow Control Enabled    

The following example displays the current status of non-Extreme optical devices:
 # sh ports 3 info detail
Port:   3        
        Virtual-router: VR-Default        
        Type:            Q+SR4       (Licensed)       or                                
                                     (Unlicensed)     or                                                               
                                     (Restricted)                          
        Random Early drop:       Unsupported        
        Admin state:     Enabled        
        Link State:      Ready        
        Link Ups:        0         Last:  --        
        Link Downs:      0         Last: --                 
        VLAN cfg:                  
                Name: Default, Internal Tag = 1, MAC-limit = No-limit, Virtual router:   VR-Default        
        STP cfg:   
                s0(disable), Tag=(none),  Mode=802.1D, State=FORWARDING         
        Protocol:                   
                Name: Default       Protocol: ANY       Match all protocols.        
        Trunking:        Load sharing is not enabled.         
        EDP:             Enabled        
        ELSM:            Disabled        
        Ethernet OAM:            Disabled        
        Learning:         Enabled        
        Unicast Flooding:        Enabled        
        Multicast Flooding:      Enabled        
        Broadcast Flooding:      Enabled        
        Jumbo:           Disabled         

        Flow Control:    Rx-Pause: Enabled        Tx-Pause:     Disabled        
        Priority Flow Control: Disabled        
        Reflective Relay:        Disabled        
        Link up/down SNMP trap filter setting:   Enabled        
        Egress Port Rate:        No-limit  (Restricted, 10 Gbps maximum)        
        Broadcast Rate:          No-limit        
        Multicast Rate:          No-limit        
        Unknown Dest Mac Rate:   No-limit        
        QoS Profile:     None configured        
        Ingress Rate Shaping :           Unsupported        
        Ingress IPTOS Examination:       Disabled
The following output displays show port info detail that has port-specific tag.
Port:   3        
            Virtual-router: None        
            Type:           BASET         
            Random Early drop:      Unsupported        
            Admin state:    Enabled with  10G full-duplex        
            Link State:     Active, 1Gbps, full-duplex        
            Link Ups:       0        Last: Wed Jun 05 00:29:24 2013        
            Link Downs:     0        Last: --         

            VLAN cfg:       Name: test, 802.1Q Tag = 200, MAC-limit = No-limit,
            Virtual router:   VR-Test                       
                Port-specific VLAN ID: 10, 11, 200                 
            Name: test2, 802.1Q Tag = 300, MAC-limit = No-limit,
            Virtual router:   VR-Default        
            STP cfg:         
            Protocol:         
            Trunking:       Load sharing is not enabled.         

            EDP:            Disabled        
            ELSM:           Disabled        
            Ethernet OAM:           Disabled        
            Learning:       Enabled        
            Unicast Flooding:       Enabled        
            Multicast Flooding:     Enabled        
            Broadcast Flooding:     Enabled        
            Jumbo:  Enabled, MTU= 9216         

            Flow Control:   Rx-Pause: Enabled       Tx-Pause: Disabled        
            Priority Flow Control: Disabled        
            Reflective Relay:       Disabled        
            Link up/down SNMP trap filter setting:  Enabled        
            Egress Port Rate:       No-limit        
            Broadcast Rate:         No-limit        
            Multicast Rate:         No-limit        
            Unknown Dest Mac Rate:  No-limit        
            QoS Profile:    None configured        
            Ingress Rate Shaping :          Unsupported        
            Ingress IPTOS Examination:      Disabled        
            Ingress 802.1p Examination:     Enabled        
            Ingress 802.1p Inner Exam:      Disabled        
            Egress IPTOS Replacement:       Disabled        
            Egress 802.1p Replacement:      Disabled        
            NetLogin:                       Disabled        
            NetLogin port mode:             Port based VLANs        
            Smart redundancy:               Enabled        
            Software redundant port:        Disabled        
            IPFIX:   Disabled               Metering:  Ingress, All Packets, All Traffic                
            IPv4 Flow Key Mask:     SIP:  255.255.255.255            DIP: 255.255.255.255                 
            IPv6 Flow Key Mask:     SIP:  ffff:ffff:ffff:ffff:ffff:ffff:ffff:ffff                                         
            DIP:   ffff:ffff:ffff:ffff:ffff:ffff:ffff:ffff          

            Far-End-Fault-Indication:       Disabled        
            Shared packet buffer:           default        
            VMAN CEP egress filtering:      Disabled        
            Isolation:                      Off        
            PTP Configured:                 Disabled        
            Time-Stamping Mode:             None        
            Synchronous Ethernet:           Unsupported        
            Dynamic VLAN Uplink:            Disabled        
            VM Tracking Dynamic VLANs:      Disabled

History

This command was first available in ExtremeXOS 10.1.

Information on ingress rate shaping was added in ExtremeXOS 11.0.

Network Login, Smart Redundancy, and rate limiting were added in ExtremeXOS 11.1.

Information on unicast, multicast, and broadcast flooding; the Port not present parameter; and autopolarity status were added in ExtremeXOS 11.2.

The netlogin parameters were added in ExtremeXOS 11.3.

The output command was modified in ExtremeXOS 12.1 so that when learning is disabled with the disabled learning port command, a new w flag appears in the output.

Link Ups and Link Downs information was added to the output and the tag value was added to the command syntax in ExtremeXOS 12.4.4.

Industrial Temperature detail added to Type field in ExtremeXOS 15.1.2.

Note

Note

The Industrial Temperature detail is only displayed only when detail is used. Without it, the output is compressed and the optic type is not displayed.

The show output was enhanced to display the SNMP ifMib ifAlias accessible string size information.

The show output was updated to include the current status of non-Extreme optical devices in ExtremeXOS 15.4.

Platform Availability

This command is available on all platforms.

Information on WAN PHY ports is available only on Summit X480 series switches, whether or not included in a SummitStack.