Unconfigures the inline power usage alarm threshold and returns threshold to the default value of 70%.
This command has no arguments or variables.
70.
This command unconfigures the PoE usage threshold setting for initiating SNMP event and EMS messages and returns the switch‘s inline power usage threshold for to 70%. The system initiates an event and message once that percentage of the budgeted power is being used.
On stand-alone switches, this PoE threshold applies to the entire switch. On modular switches, the threshold applies only to the percentage per slot of measured to budgeted power use; the threshold does not apply to the entire switch.
The system generates an additional SNMP event and EMS message once the power usage falls below the threshold again; once the condition clears.
The following command resets the inline power usage alarm threshold to 70%:
unconfigure inline-power usage-threshold
This command was first available in ExtremeXOS 11.1
This command is available on the PoE devices listed in Extreme Networks PoE Devices.