show sharing port-based keys

show sharing port-based keys {ports port_list}

Description

Displays the load sharing key values for all ports in the port_list. These values may be either default values, or configured values.

Syntax Description

ports

Specifies the ports for the load sharing.

port_list

Specifies one or more ports or slots and ports.

Default

N/A.

Usage Guidelines

Use this command to display the health-check LAGs that have been configured on the switch.

Example

The following output shows the default load sharing key values on a BlackDiamondf-X8 switch with a BDXA-10G48X module in slot 1 and a BDXA-40G24X module in slot 4 where slots 1 and 4 have not been configured to use a packet-based fabric hash. Keys assigned for port-based fabric hashing are displayed so that you can consider whether or not these keys are acceptable for a given application.

BD-X8.1 # show sharing
        port-based keysSlot 1 keys fixed for fabric
        hashing.Use “configure forwarding
        fabric hash packet slot 1” to configure.  1:1:  0  
        1:2:  1   1:3:  2   1:4:  3   1:5:  4   1:6:  5   1:7:  6   1:8:  7  
        1:9:  8   1:10:  9  1:11: 10  1:12: 11  1:13:  0  1:14:  1  1:15:  2  1:16:  3 
        1:17:  4  1:18:  5  1:19:  6  1:20:  7  1:21:  8  1:22:  9  1:23: 10  1:24: 11 
        1:25:  0   1:26:  1  1:27:  2  1:28:  3  1:29:  4  1:30:  5  1:31:  6  1:32:  7 
        1:33:  8  1:34:  9  1:35: 10  1:36: 11  1:37:  0  1:38:  1  1:39:  2  1:40:  3 
        1:41:  4  1:42:  5  1:43:  6  1:44:  7  1:45:  8  1:46:  9  1:47: 10  1:48: 11
        Slot 4 keys fixed for fabric hashing.
        Use “configure forwarding fabric hash packet slot 4” to configure.  
        4:1:  0   4:5:  1   4:9:  2  4:13:  3  4:17:  4  4:21:  5  4:25:  0  4:29:  1 
        4:33:  2  4:37:  3  4:41:  4  4:45:  5  4:49:  0  4:53:  1  4:57:  2  4:61:  3 
        4:65:  4  4:69:  5  4:73:  0  4:77:  1  4:81:  2  4:85:  3  4:89:  4  4:93:  5
The following output shows the default load sharing key values on a BlackDiamond-X8 switch with a BDXA-10G48X module in slot 1, and a BDXA-40G24X module in slot 4, where slots 1 and 4 have been configured to use a packet-based fabric hash. Note the assignment of consecutive values in the allowable range [0-15] to consecutive available ports in a slot.
BD-X8.3 # show sharing port-based keys  
  1:1:  0  1:2:  1   1:3:  2   1:4:  3   1:5:  4   1:6:  5   1:7:  6   1:8:   7  
  1:9:  8  1:10:  9  1:11: 10  1:12: 11  1:13: 12  1:14: 13  1:15: 14  1:16: 15 
 1:17:  0  1:18:  1  1:19:  2  1:20:  3  1:21:  4  1:22:  5  1:23:  6  1:24:  7 
 1:25:  8  1:26:  9  1:27: 10  1:28: 11  1:29: 12  1:30: 13  1:31: 14  1:32: 15 
 1:33:  0   1:34:  1  1:35:  2  1:36:  3  1:37:  4  1:38:  5  1:39:  6  1:40:  7 
 1:41:  8   1:42:  9  1:43: 10  1:44: 11  1:45: 12  1:46: 13  1:47: 14  1:48: 15   
 4:1:   0   4:5:  1   4:9:  2  4:13:  3  4:17:  4  4:21:  5  4:25:  6  4:29:  7 
4:33:   8  4:37:  9  4:41: 10  4:45: 11  4:49: 12  4:53: 13  4:57: 14  4:61: 15 
4:65:   0  4:69:  1  4:73:  2  4:77:  3  4:81:  4  4:85:  5  4:89:  6  4:93:  7

History

This command was first available in ExtremeXOS 15.4.

Platform Availability