On a stack:
show diagnostics {slot [slot_number]}Displays the status of the last diagnostic test run on the switch.
slot | Specifies which I/O or Fabric
module to display diagnostic status information on. Note: This
parameter is available only on modular switches.
|
A | B | Specifies which MSM/MM to
display diagnostic status information on:A specifies the MSM
installed in slot A.B specifies the MSM installed in slot
B. Note: This parameter is available only on modular
switches.
|
slot_number | Specifies the slot number of
the node on which you need to run the diagnostics. Values can be
from 1 to 8 or FM-1 to FM-4 (BDX8 only). Note: This parameter is
available only on modular switches.
|
N/A.
Use this command to display information from the last diagnostic test run on the switch.
To run diagnostics on a switch in a stack, you need to remove the node from the stacking mode, restart the node, and then run the diagnostics locally on the node. You can see the latest diagnostics results from the Master node of a stack after the node has rejoined the stack.
If you have run diagnostics, a brief summary of the overall diagnostic test is displayed.
If you have never run diagnostics on a specific slot, the switch displays a message similar to the following:
Slot-6: G8X No Diagnostics Data
If you attempt to view diagnostics information for a slot that does not have a module installed, the switch displays a message similar to the following:
Slot-7: No Module Present
The switch displays the following diagnostic information:
If you have never run diagnostics on a specific slot, the switch displays a message similar to the following:
Slot-6: G8X No Diagnostics Data
If you attempt to view diagnostics information for a slot that does not have a module installed, the switch displays a message similar to the following:
Slot-7: No Module Present
The switch displays the following diagnostic information:
If you have never run diagnostics on the switch or stack ports, the switch displays a message similar to the following:
Result: FAIL Test date run is invalid. Please run Diagnostics. Error reading diagnostics information.
This message is normal and expected if you have never run diagnostics on the switch. After you run diagnostics, you should see information about the executed test.
If you use this command on a slot where diagnostics have not been run, the switch displays messages similar to the following:
No Diagnostics Data
or
Diagnostics never run
If you try to display diagnostic test information on a slot where no module is installed, the switch displays messages similar to the following:
No Module Present
or
No card in slot
To run diagnostics on an I/O module or an MSM installed in the BlackDiamond 8800 series switch, use the following command:
run diagnostics [extended | normal] {slot [slot | A | B]}To run diagnostics on Summit family switches, use the following command:
run diagnostics [extended | normal | stack-port]Depending on the software version running on your switch or your switch model, additional or different diagnostic information might be displayed. For more information, see the command run diagnostics .
The following is sample output from a BlackDiamond X8 switch that displays the results of module diagnostics for the I/O module in slot 2:
BD-X8.5 # show diagnostics slot 2 Slot-2: BDXA-40G24X Last Test Date: Tue Jan 24 15:09:54 2012 Last Test Version: 1.7 Summary: Diagnostics Pass
The following is sample output from a BlackDiamond 8800 series switch:
Slot-2: G24X Last Test Date: Wed May 6 23:57:17 2009 Last Test Version: 12.3.0.1 Summary: Diagnostics Pass
When the version is unknown, Last Test Version reads “Unknown.”
The following is sample output from the BlackDiamond 12804 switch:
Slotnum 2 DiagResult timestamp Fri Dec 2 11:15:29 2005 Test Temperature = 41 degrees C Diag Test Version=1.0.1.2. S/N=05364-00058 ------------------------------------------------------------------------ CPU System | Passed ------------------------------------------------------------------------ Register Test | Passed ------------------------------------------------------------------------ Memory Test | Passed ------------------------------------------------------------------------ System Test | Passed ------------------------------------------------------------------------ Summary: Diagnostics Pass
The following command displays the results of the switch diagnostics for the Summit family switch:
show diagnostics
The following is sample output from this command:
Last Test Date: May-04-2006 Last Test Version: 12.3.0.1 Summary: Diagnostics Pass
When the version is unknown, Last Test Version reads “Unknown.”
This command was available in ExtremeXOS 10.1.
This command is available on all platforms.