Discontinues sending backplane diagnostic packets on modular switches.
slot | Specifies the slot to disable sending backplane diagnostic packets. |
Polling is enabled, backplane diagnostic packets are disabled.
When you use this command, backplane diagnostic packets are disabled and no longer sent by the system health checker.
If you modify the interval in the configure sys-health-check interval interval command and later disable backplane diagnostics, the configured interval for sending backplane diagnostic packets remains. The next time you enable backplane diagnostic packets, the health checker sends backplane diagnostics packets at the configured interval. For example, if you configure an interval of 8seconds, the system health checker sends backplane diagnostic packets every 8seconds.
To return to the "default" interval of 5seconds, configure the frequency of sending backplane diagnostic packets to 5 seconds using the following command:
configure sys-health-check interval 5On the BlackDiamond 8800 series switches, the following example assumes that you did not modify the interval option in the configure sys-health-check interval interval command.
The following example disables backplane diagnostics on slot 3, polling is always enabled and occurs every 5 seconds.
disable sys-health-check slot 3
This command was first available in ExtremeXOS 10.1.
This command is available only on modular switches.