unconfigure inline-power budget slot

unconfigure inline-power budget slot slot

Description

Unconfigures the inline reserved power on modular switches on the specified slot and returns the power budget on that slot to the default value.

Syntax Description

slot Specifies the slot.

Default

50 W. For X430-8p: 60W

Usage Guidelines

This command unconfigures any previously configured power budget for the specified slot and resets the budgeted power reserved for all PDs connected to this slot to 50 W. The rest of the previously configured power budget on this slot cannot be used to power other slots or PDs on other slots (unless you explicitly reconfigure the power budget for other slots).

If you specify a slot that does not have a PoE module, the system returns the following error message:

Error: Slot 2 is not capable of inline-power.

Example

The following command resets the power for slot 4 to 50 W:

unconfigure inline-power budget slot 4

History

This command was first available in ExtremeXOS 11.1.

This command was modified in ExtremeXOS 15.7.1 to be used on the Summit X430-8p.

Platform Availability

This command is available on the BlackDiamond 8000 series modules listed in Extreme Networks PoE Devices.