Shows the OpenFlow configuration state for the specified ports.
vlan |
Specifies that show output is restricted to a specified VLAN. |
vlan_name |
Specifies a named VLAN. |
None.
If the VLAN name is specified, the output is restricted to that VLAN.
The following example displays show output for all configured OpenFlow ports:
show openflow OpenFlow: Enabled Versions: OpenFlow10, OpenFlow13 Mode: Standard FDB: Off Access-list width: Single Controller : Primary Status : ACTIVE Datapath ID : 00000004967e29a4 VR : VR-Mgmt Mode : out-of-band Active Target : tcp:10.68.61.216:6633 Uptime(secs) : 360827 Controller : Secondary Not configured. Flows VLAN VID Mode Ports Active Error -------------------------------- ---- -------- ----- ------ ------ turq 99 Standard 1 0 0 azure 25 Hybrid 1 0 0 Total number of VLAN(s): 2
This command was first available in ExtremeXOS 15.3.
OpenFlow version and mode information were added in ExtremeXOS 15.7.1.
This command is available on platforms that support the appropriate license. For complete information about software licensing, including how to obtain and upgrade your license and which licenses support the BGP feature, see the Feature License Requirements document.