show inline-power slot

show inline-power slot slot

Description

Displays inline power information for the specified slot on modular switches.

Syntax Description

slot Specifies the slot.

Default

N/A.

Usage Guidelines

On modular switches, the output indicates the following inline power status for each system:
  • Configured power:
    • Enabled.

    • Disabled.

  • System power surplus.

  • Redundant power surplus.

  • Power usage threshold.

  • Disconnect precedence.

  • Legacy—The status of the legacy mode, which allows detection of many non-standard PDs.

On modular switches, the output indicates the following inline power status information for each slot:
  • Inline power status—The status of inline power. The status conditions are:
    • Enabled.

    • Disabled.

  • Firmware status—The operational status of the slot. The status conditions are:
    • Operational.

    • Not operational.

    • Disabled.

    • Subsystem failure.

    • Card not present.

    • Slot disabled.

  • Budgeted power—The amount of power, in watts, that is available to the slot.

  • Measured power—The amount of power, in watts, that currently being used by the slot.

On a stack, if you do not specify a slot number, the command operates on all active nodes. This command operates only on nodes in the active topology.

Example

The following command displays inline power information for slot 3 on a modular switch:

show inline-power slot 3

Following is sample output from this command on a modular switch:

Inline Power System Information
Configured                 : Enabled
System Power Surplus       : 1500 Watts available for budgeting
Redundant Power Surplus    :  465 Watts available for budgeting to maintain N+1
Power Usage Threshold      : 70 percent (per slot)
Disconnect Precedence      : lowest-priority
Legacy Mode                : Disabled
Budgeted       Measured
Slot  Inline-Power  Firmware Status    Power (Watts)  Power (Watts)
3     Enabled       Operational          50 W           9 W
4     Enabled       Card Not Present   ( 50 W)          n/a
7     Enabled       Operational          50 W           0 W
Note: A budget value in parentheses is not allocated from the system power

History

This command was first available in ExtremeXOS 11.1.

Platform Availability