disable inline-power slot

disable inline-power slot slot

Description

Shuts down PoE power currently provided to the specified slot.

Syntax Description

slot Disables inline power to specified slot.

Default

Enable.

Usage Guidelines

Disabling inline power to a slot immediately removes power to any connected PDs. By default, the capability to provide inline power to a slot is enabled.

Disabling a slot using this command does not change the power budgeted to a specified slot using the configure inline-power budget command; nor can that power be used by PDs connected to any other slot.

Note

Note

You can set the reserved power budget to 0 for a slot if, and only if, you first issue this command.

On a stack if you do not specify a slot number, the command operates on all active nodes. This command operates only on nodes in the active topology.

Example

The following command removes power to all PDs on slot 3:

disable inline-power slot 3

History

This command was first available in ExtremeXOS 11.1.

Platform Availability

This command is available on the PoE devices listed in Extreme Networks PoE Devices.