Shuts down PoE power currently provided to the specified slot.
| slot | Disables inline power to specified slot. | 
Enable.
Disabling inline power to a slot immediately removes power to any connected PDs. By default, the capability to provide inline power to a slot is enabled.
Disabling a slot using this command does not change the power budgeted to a specified slot using the configure inline-power budget command; nor can that power be used by PDs connected to any other slot.

Note
You can set the reserved power budget to 0 for a slot if, and only if, you first issue this command.
On a stack if you do not specify a slot number, the command operates on all active nodes. This command operates only on nodes in the active topology.
The following command removes power to all PDs on slot 3:
disable inline-power slot 3
This command was first available in ExtremeXOS 11.1.