Displays the MEP CCM database.
domain_name |
Enter the name of the domain for which you want to display the MEP CCM databases. |
association_name |
IEEE 802.1ag or ITU-T Y.1731 association name. |
port_list |
Enter the ports in the domain/association for which you want to display the CCM databases. |
up |
Enter this to display the CCM database on the UP MEP for the specified MA. |
down |
Enter this to display the CCM database on the DOWN MEP for the specified MA. |
N/A.
If you do not specify any parameters or variables, the system displays information on all CCM databases on the switch.
The name of the domain and association
Port number
MP and type
MAC address of remote end points
MEP IDs
Lifetime for CCM messages from each remote end point
Note
The TTL for the CCM messages from the MP you are working on is 3.5 times the transmission interval.
The following command displays the CCM databases on the switch:
show cfm detail
The following is sample output from this command:
# show cfm detail Domain/ Port MP Remote End-Point Remote End-Point MEP Life Flags Association MAC Address IP Address ID time Age =================================================================================== dnsname 10 1 UE 00:04:96:51:5f:15 0.0.0.0 300 3500 650 DMA dom1 VSNLMEG1 1 DE ------------- 0.0.0.0 300 11 0 SMA 1 DE ------------- 0.0.0.0 400 11 0 SMI 15 DE ------------- 0.0.0.0 300 35 0 SMA 15 DE ------------- 0.0.0.0 400 35 0 SMI dom1 short_ma_name 1 DE ------------- 0.0.0.0 300 11 0 SMA 1 DE ------------- 0.0.0.0 400 11 0 SMI 15 DE ------------- 0.0.0.0 300 3500 0 SMA 15 DE ------------- 0.0.0.0 400 3500 0 SMI dom2 VSNLMEG1 1 UE 00:04:96:51:5f:15 0.0.0.0 300 3500 750 SUA 00:11:22:33:4 VSNLMEG1 1 UE 00:04:96:51:5f:15 0.0.0.0 300 3500 760 DMA 00:11:22:33:4 short_ma_name 1 UE 00:04:96:51:5f:15 10.10.10.2 300 3500 90 DMA =================================================================================== Maintenance Point: (UE) Up End-Point, (DE) Down End-Point Flags: (S) Static Entry, (D) Dynamic Entry CCM Destination MAC: (U) Unicast, (M) Multicast Status: (A) Active, (I) Inactive NOTE: The Domain and Association names are truncated to 13 characters, Lifetime and Age are in milliseconds. =================================================================================== Total Number of Dynamic Up RMEP : 3 Total Number of Dynamic Down RMEP : 0 Total Number of Active Static RMEP : 5 Total Number of Inactive Static RMEP : 4
This command was first available in ExtremeXOS 11.4.
This command is available on all platforms.