configure erps cfm port group

configure erps ring_name cfm port [east | west] [add | delete] group group_name

Description

Associates or disassociates fault monitoring entities on the ERPS ring ports.

Syntax Description

ring_name Alphanumeric string that identifies the ERPS ring.
east East port.
west West port.
add Associates a CFM Down-MEP entity.
delete Disassociates a CFM Down-MEP entity.
group Specifies a CFM Down-MEP group.
group_name Specifies the name of the Down MEP group.

Default

N/A.

Usage Guidelines

Use this command to associate or disassociate fault monitoring entities on the ERPS ring ports.

Example

The following command associates fault monitoring on the group "group1":

configure erps ring1 cfm port east add group1

History

This command was first available in ExtremeXOS 15.3.

Platform Availability

This command is available on all platforms running ExtremeXOS.