disable inline-power slot

disable inline-power [fast | perpetual] slot slot

Description

Shuts down PoE, and fast and perpetual PoE, power currently provided to the specified slot.

Syntax Description

slot Selects the slot to disable inline power, or fast/perpetual PoE power on.
fast Disable delivery of PoE power to devices at the time of switch power on without waiting for boot up based on last saved PoE state. The default is disabled.
perpetual Disable preserving PoE power delivery to devices during reboot. Perpetual PoE is a switch-wide setting. The default is disabled.

Default

By default:
  • PoE is enabled.
  • Fast PoE is disabled.
  • Perpetual PoE is disabled.

Usage Guidelines

Disabling inline power to a slot immediately removes power to any connected PDs. By default, the capability to provide inline power to a slot is enabled. Additionally, you can disable delivery of PoE power to devices at the time of switch power on without waiting for boot up (fast PoE) based on last saved PoE state. You can also elect to not preserve PoE power delivery to devices during reboot (perpetual PoE). The default for both PoE options is disabled.

Note

Note

You can set the reserved power budget to 0 for a slot if, and only if, you first issue this command.

On a stack if you do not specify a slot number, the command operates on all active nodes. This command operates only on nodes in the active topology.

Example

The following command removes power to all PDs on slot 3:

disable inline-power slot 3
The following example turns off perpetual PoE for slot 3:
# disable inline-power perpetual slot 3

History

This command was first available in ExtremeXOS 11.1.

The fast and perpetual PoE options were added in ExtremeXOS 30.3.

Platform Availability

This command is available on the PoE devices listed in Extreme Networks PoE Devices.