Configures a created collector where Flow Monitor sends information.
collector | Specifies to send flow information to a collector. |
collector_name | Specifies the name of the created collector. Range is 32 characters. |
N/A.
You must configuresrc-ipv4-address, which is a dotted decimal representation of the local address. If not configured, the collector cannot be activated.
You must configure dst-ipv4-address, which is a dotted decimal representation of the IPv4 address of a collector. If not configured, the collector cannot be activated.
Optional configuration parameters include the following:
The following command configures a created collector with no additional parameters:
# configure flowmon collector ctest dst-ipv4-address 21.1.1.100 src-ipv4-address 21.1.1.1
This command was first available in ExtremeXOS 32.2.
This command is available on ExtremeSwitching 5520 and 5420 series switches.