create meter
Description
This command creates a meter for ingress traffic rate limiting.
Syntax Description
meter-name | Specifies the meter name. |
Default
N/A.
Usage Guidelines
Meter names must begin with an alphabetical character and may contain alphanumeric characters and underscores ( _ ), but they cannot contain spaces. The maximum allowed length for a name is 32 characters. For meter name guidelines and a list of reserved names, see Object Names in the Switch Engine 32.2 User Guide .
Example
The following command creates the meter
maximum_bandwidth:
create meter maximum_bandwidth
History
This command was available in ExtremeXOS 11.1.
Platform Availability
This command is available on ExtremeSwitching 5320, 5420, 5520, and 5720 series switches.