Disables a load-sharing group of ports, also known as a LAG.
port |
Specifies the logical port of a load-sharing group or link aggregation group (LAG). Specifies a port or a combination of the slot and port number. |
Disabled.
When sharing is disabled, the logical port retains all configuration including VLAN membership. All other member ports are removed from all VLANs to prevent loops and their configuration is reset to default values.
Any attempt to disable sharing on ports that have This command is available on ExtremeSwitching 5320, 5420, 5520, 5720 series switches. configuration is denied with the following error message:
ERROR: Sharing configuration on MLAG ports cannot be modified. Use "disable mlag port <port>" to remove port from MLAG group first.The following command disables sharing on master logical port 9, which contains ports 9 through 12, on a switch:
disable sharing 9
This command was first available in ExtremeXOS 10.1.