configure switch integrity-check image
Description
Enables or disables the NOS image integrity check feature.
Syntax Description
integrity-check | Specifies configuring integrity check. |
image | Specifies checking the loaded NOS image. |
on | Enables image integrity check feature. You are informed if the integrity check fails. |
off | Disables image integrity check feature (default). |
Default
By default, ExtremeXOS image integrity check is disabled.
Usage Guidelines
If the image integrity check is enabled, during bootup, the system checks the integrity of the NOS image, and notifies you if it has been compromised or not (an error message is logged).
To view the status and configuration of the image integrity check, use the show switch management command.
Example
The following example enables the NOS image integrity check:
# configure switch integrity-check image on
History
This command was first available in ExtremeXOS 31.1.
Platform Availability
This command is available on ExtremeSwitching 5320, 5420, 5520, and 5720 series switches.