configure cfm domain association remote-mep mac-address

configure cfm domain domain-name association association_name remote-mep mepid mac-address mac_address

Description

Allows you to modify the MAC address of an existing MEP.

Syntax Description

domain_name

Enter the domain associated with the MA you are configuring.

association_name

IEEE 802.1ag or ITU-T Y.1731 association name.

mepid

Specifies the MEP ID of the remote MEP being modified. The range is 1 to 8191.

mac_address

Specifies the MAC address for the remote MEP being modified.

Default

N/A.

Usage Guidelines

Use this command to modify a remote MEP with given MEP ID and MAC address in an existing association. Use the show cfm detail command to verify your configuration.

History

This command was first available in ExtremeXOS 12.1.

Platform Availability