Configure Auto-sense Voice Information for IP Phones
The switch applies the voice configuration on Auto-sense-enabled ports, after it discovers IP phones on the port through Link Layer Discovery Protocol (LLDP) packets.
Before you begin
If you boot the switch with a configuration file, and not through Zero Touch Fabric Configuration, you must manually enable Auto-sense on specific ports.
About this task
Perform this procedure to configure Auto-sense voice information for IP phones.
- In a non NAC, a phone is classified based on the phones LLDP signaling.
 - In a NAC, a phone is authenticated based on EAP/NEAP radius authenticated, or if configured, it is LLDP authenticated
 
Procedure
Example
Configure VLAN tagging as untagged:
Switch:1>enable Switch:1#configure terminal Enter configuration commands, one per line. End with CNTL/Z. Switch:1(config)#auto-sense voice i-sid 1234 untagged
Variable Definitions
The following table defines parameters for the auto-sense voice command.
| 
                                 Variable  | 
                            
                                 Value  | 
                        
|---|---|
| 
                                 i-sid<1-15999999>  | 
                            
                                 Specifies the service instance identifier (I-SID).  | 
                        
| 
                                 c-vid<1-4094>  | 
                            
                                 Specifies the customer VLAN ID.  | 
                        
| 
                                 untagged  | 
                            
                                 Specifies the VLAN tagging type as untagged. Note: 
                                     
                            The phone receives VLAN ID as 0 and the tagging is configured as "untagged".  | 
                        