Display IS-IS Logical Interfaces
Use the following procedure to display the Intermediate-System-to-Intermediate-System (IS-IS) logical interfaces configured on the switch.
Procedure
Examples
Example of a Layer 2 Core:
Switch:1>show isis logical-interface
============================================================================================================================
ISIS Logical Interfaces
============================================================================================================================
IFIDX NAME ENCAP L2_INFO VIDS TUNNEL L3_TUNNEL_NEXT_HOP_INFO BFD TUNNEL ORIGIN ISIS SDWAN
TYPE PORT/MLT (PRIMARY) DEST-IP PORT/MLT VLAN VRF STATUS SRC-IP MTU OPER STATE
----------------------------------------------------------------------------------------------------------------------------
1 SD-WAN-1 IP -- -- 192.0.2.3 Port1/44 4047 sd-wan disabled 192.0.2.1 ZTF 1400 UP
2 -- L2-P2P-VID Port2/1 101,201(101) -- -- -- -- disabled -- config N/A
3 -- L2-P2P-VID Port1/3 102,202(102) -- -- -- -- disabled -- config N/A
----------------------------------------------------------------------------------------------------------------------------
3 out of 3 Total Num of Logical ISIS interfaces
----------------------------------------------------------------------------------------------------------------------------
Example of a Layer 3 Core:
Switch:1>show isis logical-interface
=====================================================================================================================
ISIS Logical Interfaces
=====================================================================================================================
IFIDX NAME ENCAP L2_INFO VIDS TUNNEL L3_TUNNEL_NEXT_HOP_INFO BFD TUNNEL ORIGIN ISIS SDWAN
TYPE PORT/MLT (PRIMARY) DEST-IP PORT/MLT VLAN VRF STATUS SRC-IP MTU OPER STATE
---------------------------------------------------------------------------------------------------------------------
1 SD-WAN-1 IP -- -- 192.0.2.3 Port1/44 4047 sd-wan disabled 192.0.2.1 ZTF 1400 UP
2 SPBoIP_T1 IP -- -- 192.0.2.15 Port1/25 500 vrf23 disabled 192.0.2.16 config 1000 N/A
3 SPBoIP_T2 IP -- -- 192.0.2.224 MLT10 2 vrf24 disabled 192.0.2.22 config 1600 N/A
---------------------------------------------------------------------------------------------------------------------
3 out of 3 Total Num of Logical ISIS interfaces
---------------------------------------------------------------------------------------------------------------------
The command show isis logical-interface truncates the IS-IS logical interface name to the first 16 characters. To view the entire name (up to a maximum of 64 characters), use the command show isis logical-interface name.
Switch:1>show isis logical-interface name
===========================================================
ISIS Logical Interface name
===========================================================
ID NAME
-----------------------------------------------------------
1 SD-WAN-1
2 SPBoIP_T1
3 SPBoIP_T2
4 This_Is_A_50_Character_ISIS_Logical_Interface_Name
-----------------------------------------------------------
4 out of 4 Total Num of Logical ISIS interfaces
-----------------------------------------------------------
Variable Definitions
The following table defines parameters for the show isis logical-interface
command.
|
Variable |
Value |
|---|---|
|
name |
Displays the full name of the IS-IS logical interface (up to a maximum of 64 characters). |