Configuring Extended Edge Switching Topology with Full Automation
You can automatically configure an Extended Edge Switching topology fully or in part. This capability allows for the more rapid and accurate setup of an Extended Edge Switching architecture.

Note
Do not attach bridge port extenders (BPEs) to a partitioned port. Unconfiguring the CB removes the port partition configuration, and this causes full automation to fail.- Determines if the switch is capable of being a CB.
- Detects if any BPEs are attached.
- Enables VPEX mode on the CB.
- If you are setting up redundant CBs (see
Redundant Controlling Bridges):
- Detects the other CB.
- Creates a VLAN on only the port(s) between the CBs.
- Adds link local IP address to the VLAN.
- Creates a LAG for the port(s) between the MLAG peers.
- When the CB detects the IP address of the other CB VLAN, creates the MLAG peer.
- Enables Extended Edge
Switching
auto-configuration (see Configuring Extended Edge Switching Topology with Partial Automation (Auto-configuration), which performs the following tasks:
- Assigns the next available slot number to each BPE.
- Creates LAGs/MLAGs on cascade ports.
- Adds ports to existing cascade port LAGs.
- Defaults to stacking-support enabled mode with Extended Edge
Switching on stacking.
Note
ZTPStack will enable Extended Edge Switching upon detection of an attached BPE, but will not reboot the switch. Stacking automation (push button or easy-setup) completes this task.

Note
For full automation, the entire process can take about 6–7 minutes to complete depending upon the configuration.
- (Optional) If you are setting up redundant CBs, connect the two CBs to each other.
- Attach BPE(s).
- Ensure that full automation is enabled.
Full automation is enabled by default. Run show vpex:
# show vpex Virtual Port Extender: Disabled Auto-Configuration: Enabled Ring rebalancing: Auto Zero Touch Provisioning: Nothing Provisioned - Existing configuration present Cascade Port/MLAG Id Slot ====================
You should see Zero Touch Provisioning: Nothing Provisioned - Existing configuration present. If you see Nothing Provisioned – Disabled, run restart process ztpstack.
- Ensure that none of the following files
are present on the CB(s):
- default.xsf
- default.py
- autoexec.xsf
- autoexec.py
For information about locating and deleting files on the switch, see Using the ExtremeXOS File System.
- Ensure that the CB(s) do not have a
configuration. Run unconfigure switch {all | erase [all | nvram]}. Use either:
- unconfigure switch—removes configuration, but leaves other settings intact.
- unconfigure switch all—removes configuration and resets all settings to factory defaults (recommended).
- Reboot the CB(s).
- The configuration applied by automation is not automatically saved. Save the
configuration:
- Manually: save configuration {primary | secondary | existing-config | new-config}
- Automatically: save configuration automatic {every minutes {primary | secondary | existing-config | new-config} | never}
For information about troubleshooting an Extended Edge Switching topology, see Troubleshooting an Extended Edge Switching Topology.

Note
To avoid having automation start if you do want it to, run terminate vpex ztp or perform some configuration prior to attaching BPEs or have a default.xsf (or other similar file) file in pl