configure cfm domain association destination-mac-type

configure cfm domain domain-name association association_name destination-mac-type [unicast | multicast]

Description

Allows you to choose the destination MAC type for sending CFM PDUs for an MA.

Syntax Description

domain_name

Enter the domain associated with the MA you are configuring.

association_name

IEEE 802.1ag or ITU-T Y.1731 association name.

unicast

CFM PDUs are sent to the unicast MAC address configured in static remote MEP creation.

multicast

CFM PDUs are sent to the standard multicast destination address.

Default

Multicast.

Usage Guidelines

Use this command to change the MAC type on a previously configured MA. If multicast is selected, CFM PDUs are sent to the standard multicast destination. If unicast is selected, CFM PDUs are sent to the unicast MAC address configured in static remote MEP creation.

Use the show cfm command to verify your configuration.

History

This command was first available in ExtremeXOS 12.1.

Platform Availability

This command is available on the Summit X450-G2, X460-G2, X670-G2, X770, and ExtremeSwitching X440-G2, X620, X690, X870 series switches.