configure cfm domain association ports end-point ccm

configure cfm domain domain_name association association_name ports port_list end-point [up | down ] ccm [disable | enable]

Description

This command is used to enable or disable sending CCMs on a given MEP.

Syntax Description

domain_name

Enter the domain associated with the MA you are configuring.

association_name

IEEE 802.1ag or ITU-T Y.1731 association name.

port_list

Enter the port number you want to configure as either an UP or DOWN MEP.

Default

Enabled.

Usage Guidelines

Each MA needs at least two MEPs that can reach each other to exchange CCM messages.

Note

Note

Ensure that you assigned the port number correctly to the UP MEP and to the DOWN MEP, or the CCM messages go in the wrong direction.

These ports must already be in the MA (VLAN (Virtual LAN) or VMAN) prior to assigning a MEP function to them. If you try to assign a port not in the MA as an end-point, the system returns the following message:

The following port(s) <portlist> are not part of the associations VLAN.

Use the show cfm command to verify your configuration.

Example

configure cfm domain "MD1" association "MD1v1" ports 17 end-point down delete group "eapsCfmGrp"

History

This command was first available in ExtremeXOS 12.3.

Platform Availability

This command is available on the Summit X450-G2, X460-G2, X670-G2, X770, and ExtremeSwitching X440-G2, X620, X690, X870 series switches.