disable vman cep egress filtering ports
Description
Disables the egress filtering of CVIDs that are not configured in the CVID map for a CEP.
Syntax Description
port_list | Specifies a list of ports. |
all | Specifies all switch ports. |
Default
Egress CVID filtering is disabled.
Usage Guidelines
To view the configuration setting for the egress CVID filtering feature, use the show ports information command.

Note
When CVID egress filtering is enabled, it reduces the maximum number of CVIDs supported on a port. The control of CVID egress filtering applies to fast-path forwarding. When frames are forwarded through software, CVID egress filtering is always enabled.Example
The following example disables egress CVID filtering on port 1:
disable vman cep egress filtering port 1
History
This command was first available in ExtremeXOS 12.6.
Platform Availability
This command is available on ExtremeSwitching X435, X440-G2, X450-G2, X460-G2, X465, X590, X620, and X695 series switches.