configure stpd loop-protect event-window
Description
Configures the interval for which loop protect events are counted by the loop protect event threshold.
Syntax Description
stpd_name | Specifies an STPD name on the switch. |
interval | The length of the interval, in seconds, over which the loop protect event threshold is defined. The valid range is 0–255 seconds. |
Default
By default the interval is set to 180 seconds.
Usage Guidelines
None.
Example
The following example sets the loop protect event window to 120 seconds for STP domain r1.
configure stpd r1 loop-protect event-window 120
History
This command was first available in ExtremeXOS 15.7.1.
Platform Availability
This command is available on ExtremeSwitching X435, X440-G2, X450-G2, X460-G2, X465, X590, X620, and X695 series switches.