Configuring the SLPP by VLAN
Activate SLPP on a VLAN to enable forwarding of the SLPP packet over the VLAN. This configuration controls the boundary of SLPP-PDU transmission.
Before you begin
-
Enable SLPP globally before you configure it on a VLAN.
Procedure
- In the navigation tree, expand the following folders: .
- Click SLPP.
- Click the VLANS tab.
- Click Insert.
- Click the VlanId ellipses (...).
- Select the desired VLAN ID.
- Click Ok.
- Select SlppEnable.
- Click Insert.
Insert VLANs Field Descriptions
Use the data in the following table to use the Insert VLANS dialog box.
Name |
Description |
---|---|
VlanId |
Specifies the VLAN ID in the range of 1 to 4059. By default, VLAN IDs 1 to 4059 are configurable and the system reserves VLAN IDs 4060 to 4094 for internal use. On switches that support the vrf-scaling and spbm-config-mode boot configuration flags, if you enable these flags, the system also reserves VLAN IDs 3500 to 3998. VLAN ID 1 is the default VLAN and you cannot create or delete VLAN ID 1. |
SlppEnable |
Activates SLPP on the selected VLAN. The SLPP packet transmission and reception process is active only if you enable the SLPP operation. If you disable the SLPP operation, the following occurs:
The default is enabled. |