View the Remote I-SID Forwarding Database

Note

Note

This procedure only applies to the VSP 7400 Series.

About this task

Perform this procedure to view the remote I-SID forwarding database (FDB) on the switch.

Note

Note

To view the T-UNI I-SID FDB entries filtered on a port that is part of an MLT, you must mention the MLT ID in the option for the port.

Procedure

  1. In the navigation pane, expand the Configuration > IS-IS folders.
  2. Select ISID Remote.
  3. Optional: Select the Filter button to filter the rows on basis of specific criteria.

FDB Field Descriptions

Use data in the following table to use the FDB tab.

Name

Description

IsidId

Specifies the service interface identifier (I-SID).

Address

Specifies the MAC address of the port assigned to the specific I-SID or C-MAC learned on the particular I-SID.

Status

Specifies the learning status of the associated MAC.

Port

Specifies the port on which the MAC is learned for the specific I-SID.

PortType

Specifies if the MAC address is learned locally or on an NNI port from a remote destination.

RemoteMacDestAddr

Specifies the virtual BMAC address or system-ID of the remote destination.

RemoteMacBVlanId

Specifies the B-VLAN ID on which the remote destination was discovered.

RemoteMacDestSysName

Specifies the remote destination system name.

Cvid

Specifies the customer VLAN ID of the associated Switched UNI port.