Configuring ELAN endpoints

Use the following procedure to configure information associated with ELAN end points.

Procedure

  1. In the navigation pane, expand the Configuration > Edit folders.
  2. Click VTEP.
  3. Click the Elan End Points tab.
  4. In the Vnid field, specify the VNID associated with this ELAN.
  5. In the Cvid field, specify the customer VLAN ID.
  6. In the IfIndex field, specify the interface index for this ELAN endpoint.
  7. Click Apply.

Elan End Points field descriptions

Use the data in the following table to use the Elan End Points tab.

Name

Description

Vnid

Specifies a value that uniquely identifies the VNID of this ELAN tunnel end point.

Cvid

Specifies a value that uniquely identifies the customer VLAN ID of this ELAN endpoint.

The switch reserves the following VLAN IDs:

  • VLAN ID 1 is the default VLAN and you cannot create or delete VLAN ID 1.

  • VLAN IDs 4060 to 4094 are reserved for internal use.

  • VLAN IDs 3500 to 3999 are reserved if you enable VRF scaling and SPBM mode.

  • VLAN ID 4095 is not used.

  • VLAN ID 4096 is reserved for untagged traffic.

IfIndex

Specifies the interface index for the MLT or port for this ELAN endpoint.

Isid

Specifies the I-SID associated with this VNID.