Note
DEMO FEATURE - Read Only User for EDM is a demonstration feature on some products. Demonstration features are provided for testing purposes. Demonstration features are for lab use only and are not for use in a production environment. For more information, see VOSS Feature Support Matrix.
Perform this procedure to enable the web server RO user, which is disabled by default after a software upgrade.
enable
configure terminal
web-server read-only-user enable
Switch:1>enable Switch:1#configure terminal
Enable the default ro username:
Switch1:(config)#web-server read-only-user enable
Display the output of the show web-server command with the ro username enabled:
Switch:1(config)#show web-server
Web Server Info :
        Status                    : on
        Secure-only               : enabled
        TLS-minimum-version       : tlsv12
        RO Username Status        : enabled
        RO Username               : jones6
        RO Password               : ********
        RWA Username              : smith2
        RWA Password              : ********
        Def-display-rows          : 30
        Inactivity timeout        : 900 sec
        Html help tftp source-dir : 
        HttpPort                  : 80
        HttpsPort                 : 443
        NumHits                   : 87
        NumAccessChecks           : 4
        NumAccessBlocks           : 0
        NumRxErrors               : 73
        NumTxErrors               : 0
        NumSetRequest             : 0
        Minimum password length   : 8
        Last Host Access Blocked  : 0.0.0.0
        In use certificate        : Self signed