Note
DEMO FEATURE - Read Only User for EDM is a demonstration feature on some products. Demonstration features are provided for testing purposes. Demonstration features are for lab use only and are not for use in a production environment. For more information, see VOSS Feature Support Matrix.
Perform this procedure to enable the web server RO user, which is disabled by default after a software upgrade.
enable
configure terminal
web-server read-only-user enable
Switch:1>enable Switch:1#configure terminal
Enable the default ro username:
Switch1:(config)#web-server read-only-user enable
Display the output of the show web-server command with the ro username enabled:
Switch:1(config)#show web-server Web Server Info : Status : on Secure-only : enabled TLS-minimum-version : tlsv12 RO Username Status : enabled RO Username : jones6 RO Password : ******** RWA Username : smith2 RWA Password : ******** Def-display-rows : 30 Inactivity timeout : 900 sec Html help tftp source-dir : HttpPort : 80 HttpsPort : 443 NumHits : 87 NumAccessChecks : 4 NumAccessBlocks : 0 NumRxErrors : 73 NumTxErrors : 0 NumSetRequest : 0 Minimum password length : 8 Last Host Access Blocked : 0.0.0.0 In use certificate : Self signed