Configuring LST

Note

Note

DEMO FEATURE - Link-state tracking (LST) is a demonstration feature on some products. Demonstration features are provided for testing purposes. Demonstration features are for lab use only and are not for use in a production environment. For more information on feature support, see VOSS Feature Support Matrix.

Use this procedure to configure LST groups.

Procedure

  1. In the navigation pane, expand the Configuration > Edit folders.
  2. Click Link State Tracking
  3. Click the Link State Tracking tab.
  4. Choose a GroupId row to configure.
  5. To add upstream ports to the LST group, double click the UpstreamPortList field, select the upstream ports to add, then click OK.
  6. To add downstream ports to the LST group, double click the DownstreamPortList field, select the upstream ports to add, then click OK.
  7. To add an upstream MLT to the LST group, double click the UpstreamMltList field and enter an upstream MLT ID.
  8. To add a downstream MLT to the LST group, double click the DownstreamMltList field and enter an upstream MLT ID.
  9. To enable a LST group, double click the Enabled field and select true.
  10. To activate the LST group configuration, click Apply.
  11. View the OperState field of the LST groups to verify the current operating state.

Link State Tracking field descriptions

Use the data in the following table to use the Link State Tracking tab.

Name

Description

GroupId

Specifies the LST group number between 1 and 48.

Enabled

Specifies if the LST group is enabled. Values are true or false. Default is false.

UpstreamPortList

Specifies upstream interface ports in the LST group.

DownstreamPortList

Specifies downstream interface ports in the LST group.

UpstreamMltList

Specifies an upstream multi-link trunk in the LST group.

DownstreamMltList

Specifies a downstream multi-link trunk in the LST group.

OperState

Displays the current operating status of the LST group. Values are up, down, or notConfigured.