Configure an IS-IS Manual Area

Use the following procedure to configure an IS-IS manual area.

Procedure

  1. In the navigation pane, expand Configuration > IS-IS.
  2. Select IS-IS.
  3. Select the Manual Area tab.
  4. Select Insert.
  5. In the AreaAddr field, type the Area Address.
  6. Select Insert.

Manual Area or Manual Area Remote Field Descriptions

Use the data in the following table to use the Manual Area or Manual Area Remote tab.

Name

Description

AreaAddr

Specifies the IS-IS manual area. Valid value is 1-13 bytes in the format <xx.xxxx.xxxx...xxxx>. Only one manual area is supported. Use the same manual area across the entire SPBM cloud. For IS-IS to operate, you must configure at least one manual area.