Configuring SPBM on an interface

Use the following procedure to configure SPBM on an interface.

Procedure

  1. In the navigation pane, expand Configuration > IS-IS.
  2. Click IS-IS.
  3. Click the Interfaces tab.
  4. Click the SPBM button.
  5. In the Interfaces SPBM tab, click Insert.
  6. Click Insert.

SPBM field descriptions

Use the data in the following table to use the Interfaces SPBM tab.

Name

Description

Index

Specifies an Index value for the SPBM interface.

SpbmId

Specifies the SPBM ID.

State

Specifies whether the SPBM interface is enabled or disabled.

Type

Configures the SPBM instance interface-type on the IS-IS interface located on the specified port or MLT: ptpt or bcast. Only the point-to-point (ptpt) interface type is supported.

L1Metric

Configures the IS-IS Interface level 1 metric on the specified port or MLT. The default value is 10.

Origin
Note:

Exception: not supported on VSP 8600 Series and XA1400 Series.

Specifies the source of the SPBM instance configuration, either manually configured through CLI or EDM or dynamically configured through Auto-sense.