Associate an I-SID with an ACL
Note
This procedure does not apply to VSP 8600 Series or XA1400 Series.
Before you begin
-
The inVsn ACL exists.
-
This I-SID is already configured on the fabric node.
About this task
For inVsn ACL types, specify the I-SID associated with the customer VLAN (Layer 2 VSN), the customer VRF (Layer 3 VSN), or the IP Shortcut.
Note
For IP Shortcut traffic, the inVsn ACL match type must be both. In this case, the I-SID is zero (0).
Procedure
Variable definitions
Use the data in the following table to use the filter acl i-sid command.
Variable |
Value |
---|---|
<acl-id> |
Specifies the ACL ID. Use the CLI Help to see the available range for the switch. |
<0–15999999> |
Specifies the I-SID associated with the customer VLAN (Layer 2 VSN) or the customer VRF (Layer 3 VSN). This I-SID must already be configured on the fabric node. The InVSN Filter supports IP Shortcut traffic if the inVsn ACL match type is both. In this case, the I-SID is zero (0). Important:
You can specify a Switched UNI I-SID if the I-SID is associated with a platform VLAN. |