Configure Connectivity Associations
Use the following procedure to configure connectivity associations (CA) using EDM.
Note
-
You can configure MACsec on physical ports only. However, the physical ports can belong to an MLT trunk group that includes: Split MultiLink Trunking (SMLT), distributed MultiLink Trunking (DMLT), or Link aggregate group (LAG).
-
MACsec encryption and decryption algorithms follow either the AES-GCM-128 or the AES-GCM-256 standard, depending on the configured MAC-sec cipher suite. The default is the AES-GCM-128 standard.
Procedure
- In the navigation pane, expand .
- Select Chassis.
- Select the MACSec tab.
-
Select Insert.
- Select Apply.
MACSec Field Descriptions
Use the data in the following table to use the MACSec tab.
Name |
Description |
---|---|
AssociationName |
Specifies the connectivity-association name as an alpha-numeric ASCII string up to 16 characters long. The device uses this value for the connectivity-association key name (CKN). Tip:
Configure the CKN in multiples of 4 characters to avoid MKA interoperability issues between VOSS switches and EXOS or Switch Engine switches. For example, Macsecma (8 chararcters) or Macsecmka123 (12 characters) are valid, but Macsec (6 characters) is not valid. |
AssociationKey |
Specifies the connectivity-association key (CAK) value as a 32-character (128-bit) or a 64 character (256-bit) hexadecimal string. Note:
Always select the 128-bit CAK value for AES-GSM-128 and the 256-bit CAK value for AES-GSM_256. |
AssociationPortMembers |
Specifies the set of ports for which this connectivity association is associated. |
AssociationTxKeyParity |
Specifies Tx key parity using the following values:
|