Display the MAC Addresses in the VNID FDB

Note

Note

Exception: only supported on VSP 7200 Series, VSP 7400 Series, VSP 8200 Series, and VSP 8400 Series.

Use the following procedure to display the MAC addresses in the VNID forwarding database.

Procedure

  1. Enter Privileged EXEC mode:

    enable

  2. Display all the VNIDs in the FDB table or use one of the options to specify a particular VNID:

    show vnid mac-address—entry [<1–16777215> | port <{slot/port[/sub-port] [-slot/port[/sub-port]] [,...]}> | mac <0x00:0x00:0x00:0x00:0x00:0x00> | remote]

Example

Switch:1# show vnid mac-address—entry
==========================================================================
                              VNID Fdb Table  
==========================================================================
VNID         STATUS  	   MAC-ADDRESS           INTERFACE         TYPE
--------------------------------------------------------------------------
11000065     learned     00:00:5e:00:01:01      vtep_56          REMOTE
14000100     learned     a4:25:1b:51:a5:04      vtep_67          REMOTE
14000100     learned     a4:25:1b:52:a5:04      vtep_67          REMOTE
14000100     learned     a4:25:1b:52:bd:03      vtep_2           REMOTE

c: customer vid   u: untagged-traffic

All 4 out of 4 Total Num of vnid FDB Entries displayed
--------------------------------------------------------------------------