Feature |
Product |
Release introduced |
---|---|---|
Authentication for Privileged EXEC CLI Command Mode |
5320 Series |
Fabric Engine 8.6 |
5420 Series |
VOSS 8.4 |
|
5520 Series |
VOSS 8.4 |
|
5720 Series |
Fabric Engine 8.7 |
|
7520 Series |
Fabric Engine 8.10 |
|
7720 Series |
Fabric Engine 8.10 |
|
VSP 4450 Series |
VOSS 8.2 |
|
VSP 4900 Series |
VOSS 8.2 |
|
VSP 7200 Series |
VOSS 8.2 |
|
VSP 7400 Series |
VOSS 8.2 |
|
VSP 8200 Series |
VOSS 8.2 |
|
VSP 8400 Series |
VOSS 8.2 |
|
VSP 8600 Series |
VSP 8600 8.0 |
|
XA1400 Series |
VOSS 8.2 |
For enhanced security, you can enable user authentication to enter Privileged EXEC command mode. Use the sys priv-exec-password command to enable password authentication.
After you enable password authentication for Privileged EXEC command mode, the system prompts you to enter a password to access Privileged EXEC command mode from User EXEC command mode. You must enter the same password that you used to log on to the switch.
The same username and password used to Telnet or SSH to the switch is used to access Privileged EXEC command mode when authentication is enabled.
RADIUS and TACACS+ protocols are supported. If RADIUS and TACACS+ servers are not reachable, access to Privileged EXEC command mode is denied. You must open a new session and type the same username and password used to Telnet or SSH to the switch.